User's Manual
W W W . D A N G E R O U S P O W E R . C O M
32 33
GLOBAL SETUP MENU (CONTINUED)
Determines which ring mode to ramp to: Burst, Reactive, Full Auto,
or Percent ramping.
In Burst Mode, it is the number of shots in a burst. In Reactive
Mode, it is the number of shots red with each trigger pull and
release. In Percent ramping, it is the percentage of ramping used
(Percentage = Ramp Firing Value x 100).
Determines the amount of time the trigger can be at rest and still
remain in the current ramping stage before reverting back to Semi
Mode. This time value is entered in seconds. If this setpoint is
zero, it will reset ramping when the trigger is released, or when your
trigger pull rate drops below the Ramp Pull Rate setpoint.
RESET MENU
The Reset Menu allows you to individually reset proles, statistics, or
your entire marker to factory default settings. Trigger scroll to the item
you want to reset. To select the item you wish to reset, pull and hold the
trigger. A conrmation screen will then ask you to conrm that you want
to reset the item. Pull and hold to conrm.
MARKER SETPOINTS
This value sets amount of time (in milliseconds) the trigger must
remain inactive prior to accepting a new trigger pull. Lowering this
value can cause your marker to re erratically when making
successive trigger pulls. Raising this value will prevent erratic ring
and provide reliable ring in sync with your trigger pulls.
This setting allows you to adjust how long the solenoid is energized
(in milliseconds). Higher Dwell times will consume more power and
air when the solenoid is energized. Lower Dwell times consume
less power when the solenoid is energized. Lowering this value too
much may prevent the solenoid valve from opening altogether.
This setting allows you to add additional Dwell time (in milliseconds)
to your solenoid Dwell setting. This will only affect the rst shot red
after the Bolt Stick Reset Time is exceeded.
NOTE
YOU SHOULD ONLY USE THIS SETTING IF YOU
EXPERIENCE FIRST SHOT DROP OFF.