USER MANUAL
TABLE OF CONTENT Table of Content.........................................................................................................2 Warning.....................................................................................................................3 Pending No................................................................................................................3 Statement of Liability.................................................................................................
WARNING Eye prot ect ion must be worn at all times by the user and any person loca ted in the rang e of an act ively used paint ball marker. The eye prot ect ion gea r must be app roved and desi gned for paint ball use. The Fusi on marker is not a toy! Misuse or carel ess use can cau se ser ious injury or dea th. Please read the operation manu al and warranty card before usi ng. Always use a barr el block ing dev ice.
DISCLAIMER Notice is hereby given that this owner' s manu al is part of the article owned in whole by the manu fact urer , known as indicat ed by this discl aimer and all illust rations within the manu al. All rights for manu fact uri ng and reprod ucing of such articles or any part thereof are reser ved by the manu fact urer . Neither sai d article nor any part thereof may be manu fact ured or reprod uce d in any way exc ept by the written authori zat ion from the manu fact urer .
FEATURES 250 to 300 psi operating press ure Uses N2 or com press ed air for air sou rce Air-r am elect ronic desi gn Cock er com pati ble barr el thread ACS (anti -cho p syst em) Delrin sel f-lubricat ing field-st rip bolt Quick-st rip bolt / striker syst em Senso r trigger with 2-st ep adjust ing LED user interface (Semi / ramping) BPS (cap at 20) Senso r Bounce -bea m sensor syst em Blade style trigger for lighter pull Low-rise feed nec k 3-D mach ined body milling Dual regu lator syst em ASA (air syst em
AIR SOURCE Fusi on will work with N 2 and com press ed air. Before attach ing the air syst em onto Fusi on, ensu re the bottom line dev ice is in place. Always use the front han dle regu lator for ensu ring the operating press ure is at 250 to 300 psi . Before attach ing the air syst em, put lubricat ion on the o-r ing of the air tank . If there is an on/off switch present ed on the air syst em, shu t the air syst em off before con nec ting it onto Fusi on.
PRESSURE ADJUSTMENT Before attach ing the air syst em, ensu re the air syst em ada pter is in place. OPR: Turni ng the adjust ment scr ew clock wise, or in, will lower the OPR's output press ure. Turni ng the adjust ment scr ew cou nterclock wise, or out, will raise the OPR's output press ure. LPR: Turni ng the adjust ment scr ew clock wise, or in, will lower the LPR's output press ure. Turni ng the adjust ment scr ew cou nterclock wise, or out, will raise the LPR's output press ure.
TRIGGER ADJUSTMENT The two adjust ment scr ews are loca ted on the left side of the frame abo ve the trigger guard. The scr ew on the top con trols the over-trave l. By turni ng this scr ew you can adjust how far the trigger will trave l after it reach es the firing point. The scr ew below con trols the forw ard trave l. Screwing it in will sho rten the trigger's leng th of pull. LED INTERFACE OPERATION Before operating the PC board of Fusi on, ensu re the barr el block ing dev ice is in place.
Red light flashi ng eve ry 5 secon ds Stand by mode (autom atic after 30 secon ds of non-use) Blue light blinking rapidl y Senso r syst em OFF Blue light blinking slowly Senso r syst em ON and marker NOT load ed Blue light stead y Senso r syst em ON and marker load ed DEACTIVATION Press and hold the power button“A”for 4 secon ds. LED turn off after releasi ng the han d. BOARD ADJUSTMENT Using a HEX tool, remove the 2 scr ews loca ted on the top and button of gri p with the Fusi on is pointing to the left.
SENSOR SYSTEM MAINTENANCE The sensor syst em must be kep t clean for optimal perf orm anc e. Please follow the inst ructi ons below for clean ing and maintena nce : 1. Remove the two scr ews loca ted on the top and bottom of gri p usi ng a HEX tool. 2. Clean the area thoroughly with cott on swab. 3. Replace the sensor syst em and the cov er. 4. Replace the scr ews bac k onto the sensor syst em cov er.
FIRING VALVE MAINTENANCE Follow the below inst ructi on to remove the firing valve assem bly caref ully for clean ing and maintena nce : 1. Remove the ASA (air syst em ada pter) hoses. 2. Remove the two scr ews loca ted on the top and bottom of gri p usi ng a HEX tool. 3. Disass emble the sol eno id line and sensor eye syst em. 4. Remove the two invisible scr ews usi ng a HEX tool. 5. Sepa rate the body and gri p frame. 6. Turn the firing valve scr ew (found under the body) cou nterclock wise. 7.
TROUBLESHOOTING PROBLEM Pressure gauge will not move Fusion will not turn on Fusion will not fire POSSIBLE CASUE The pressure used was too hi SOLUTION Replace the gauge Not activated Hold down operating button for more than 4 seconds Low battery power Change battery Battery is connected incorrectly to the PC board Check to see if the battery cable were connected correctly to the terminal Low battery power Change battery Low pressure air Refill the air system Solenoid may be out of place Open