Service manual

8.3.13 DC Coil
1. Remove 5 screws (T20) on the potted coil.
2. Remove the DC coil.
Reinstall in the reverse order.
1
2
130BC082.11
Illustration 8.21 DC Coil
1 Bus bar
2 DC coil
Table 8.21
8.3.14
IGBT
1. Remove 2 screws (T20) from each of the 3 IGBTs.
CAUTION
The IGBTs and the heatsink have thermal paste on them.
Wear protective gloves as the paste is poisonous.
2. Remove all IGBTs.
Reinstall in the reverse order.
130BC083.11
1
Illustration 8.22 IGBT
1 IGBT
Table 8.22