Service manual
7.6 H10 Frame Size Disassembly and
Assembly Instructions
7.6.1 Control Card and Control Card
Mounting Plate
1. Remove the LCP cradle. LCP cradle can be
removed by hand.
2. Remove 3 screws (T10) securing the control card
mounting plate to the control assembly support
bracket.
3. Carefully lift out the control card.
Reinstall in the reverse order.
130BC101.11
2
3
1
Illustration 7.26 Control Card and Control Card Mounting Plate
1
LCP
2 Control card mounting plate
3 Control card
Table 7.26
7.6.2
Power Card Cover
1. Press and loosen the 3 barbs at the bottom, and
the 3 barbs at the top.
2. Remove the power card cover.
Reinstall in the reverse order. Join the mounting snaps.
130BC103.11
1
Illustration 7.27 Power Card Cover
1 Power card cover
Table 7.27
H-Frame Size Disassembly a...
VLT
®
HVAC Basic Drive Service Manual
MG90X202 - VLT
®
is a registered Danfoss trademark 73
7 7