Service manual

7.4.10 Capacitor Bank
1. Remove the foil.
2. Remove the 6 screws on the bottom plate.
3. Remove the bottom plate.
4. Remove the 4 screws (T20) from the capacitor
mounting plate.
5. Remove the mounting plate.
6. Turn the capacitor bank upside-down.
7. Remove the hex nut with a hex 19 key.
8. Remove the capacitor.
Reinstall in the reverse order.
130BC348.10
1
2
3
Illustration 7.15 Capacitor Bank
1
Foil
2 Bottom plate
3 Capacitor bank
Table 7.15
7.5
H8 Frame Size Disassembly and
Assembly Instructions
7.5.1 Control Card and Control Card
Mounting Plate
1. Remove the LCP by pressing the barbs on the
side.
2. Remove the foil.
3. Remove the 3 screws (T10).
4. Gently, lift off the control card.
5. Press the barb on the LCP ribbon cable and pull
it out of the control card mounting plate.
6. Remove the mounting plate.
Reinstall in the reverse order.
H-Frame Size Disassembly a...
VLT
®
HVAC Basic Drive Service Manual
66 MG90X202 - VLT
®
is a registered Danfoss trademark
77