Service manual
7.3.3 DC Coil
1. Remove the 4 screws on the DC coil cover to
access the DC coils.
2. Remove the 4 screws to loosen the cables from
the DC Link card.
3. Remove the 6 screws on the DC coils (3 screws
on each coil).
4. Remove the coils.
Reinstall in the reverse order.
130BC109.11
1
2
Illustration 7.3 DC Coil
1
DC coil cover
2 DC coils
Table 7.3
7.3.4
DC Link Card
1. Remove the 6 screws on coil mounting plate.
2. Remove the coil mounting plate.
3. Loosen the 4 screws from the DC Link card.
4. Press one of the barbs to loosen the link card.
5. Unplug the 10-pin ribbon cable and the filter
cable.
6. Remove the DC Link card.
Reinstall in the reverse order. Join the mounting snaps.
130BC110.11
3
2
1
Illustration 7.4 DC Link Card
1
Coil mounting plate
2 Capacitor bank metal cover
3 DC link card
Table 7.4