Operating instructions

VLT
®
5000 FLUX
Programming
Introduction
Parameter group 3xx selects the analogue and digital inputs and outputs to the desired function. Also scaling
of the inputs and outputs is performed in this group. Inputs: Max frequency on inputs terminal 16, 17, 18, 19,
27, 32, and 33 is 5 kHz. (24Vpp). Max frequency on inputs terminal 29 is 65 kHz (24Vpp).
Max frequency for the encoder inputs terminal 73 - 78 is 250 kHz (5Vpp). Outputs: Analogue outputs terminal
42 and 45 are scaleable current outputs. Max frequency on digital outputs terminal 26 and 46 is 50kHz.
PNU Parameter Factory setting Range Changes 4-Setup
Conver-
sion Data
# description during operation index type
300 T
Terminal 16, input
Reset Yes Yes 0 5
301 T
Terminal 17, input
Freeze reference Yes Yes 0 5
302 T
Terminal 18 Start, input
Start Yes Yes 0 5
303 T
Terminal 19, input
Reversing Yes Yes 0 5
304 T
Terminal 27, input
Coasting stop, inverse Yes Yes 0 5
305 T
Terminal 29, input
Jog Yes Yes 0 5
306 T
Terminal 32, input
Choice of setup, msb/speed up Yes Yes 0 5
307 T
Terminal 33, input
Choice of setup, lsb/speed down Yes Yes 0 5
308 T
Terminal 53, analogue input voltage
Reference Yes Yes 0 5
309 T
Terminal 53, min. scaling
0.0 V 0.0 - 10.0 V Yes Yes -1 5
310 T
Terminal 53, max. scaling
10.0 V 0.0 - 10.0 V Yes Yes -1 5
311 T
Terminal 54, analogue input voltage
No operation Yes Yes 0 5
312 T
Terminal 54, min. scaling
0.0 V 0.0 - 10.0 V Yes Yes -1 5
313 T
Terminal 54, max. scaling
10.0 V 0.0 - 10.0 V Yes Yes -1 5
314 T
Terminal 60, analogue input current
Reference Yes Yes 0 5
315 T
Terminal 60, min. scaling
0.0 mA 0.0 - 20.0 mA Yes Yes -4 5
316 T
Terminal 60, max. scaling
20.0 mA 0.0 - 20.0 mA Yes Yes -4 5
317 T
Time out
10 sec. 0 - 99 sec. Yes Yes 0 5
318 F
Function after time out
Off Yes Yes 0 5
319 T
Terminal 42, output
0-n
MAX
0-20 mA Yes Yes 0 5
321 T
Terminal 45, output
0-n
MAX
0-20 mA Yes Yes 0 5
323 R
Relay 01, output
No operation Yes Yes 0 5
324 R
Relay 01, ON delay
0.00 sec. 0.00 - 600.00 sec. Yes Yes -2 6
325 R
Relay 01, OFF delay
0.00 sec. 0.00 - 600.00 sec. Yes Yes -2 6
326 R
Relay 04, output
No operation Yes Yes 0 5
327 P
Pulse reference, max. frequency
100 - 65000 Hz 5000 Hz Yes Yes 0 6
329 E
Encoder feedback pulse/rev.
1024 pulses/rev. 500 - 10.000 pulses/rev. Yes Yes 0 6
341 T
Terminal 46, digital output
No operation Yes Yes 0 5
342 T
Terminal 46, output, pulse scaling
5000 Hz 1 - 50000 Hz Yes Yes 0 6
350 E
Encoder monitoring
OFF No No 0 5
351 E
Encoder direction
Normal No Yes 0 5
355 T
Terminal 26, digital output
No operation Yes Yes 0 5
356 T
Terminal 26, output, pulse scaling
5000 Hz 1 - 50000 Hz Yes Yes 0 6
357 T
Terminal 42, Output minimum scaling
0 % 000 - 100% Yes Yes 0 6
358 T
Terminal 42, Output maximum scaling
100% 000 - 500% Yes Yes 0 6
359 T
Terminal 45, Output minimum scaling
0 % 000 - 100% Yes Yes 0 6
360 T
Terminal 45, Output maximum scaling
100% 000 - 500% Yes Yes 0 6
361 M
Max Tracking Error
OFF 000 - 999 rpm Yes Yes 0 6
362 K
KTY Sensor Type
KTY1 KTY 1-3 No Yes 0 5
See also Operation and Display for further
information regarding Changes during operation,
4-Setup and Conversion index.
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.55.A7.02 - VLT is a registered Danfoss trademark
89