Operating instructions

VLT
®
5000 FLUX
Local and remote control
The frequency converter can be operated manually
(Local control) or remotely (Remote control). The
following is a list of the functions/commands given
via the control panel, the digital inputs or the serial
communication port in the two situations (modes).
Operation Site
Remote Local
Control Command FC Profile Local Local mixed
LCP start/stop X
1)
XX
LCP jog X X X
LCP reset X X X
LCP reversing -
2)
X-
Mains failure inverse X X X
Reset X X X
Ramp 2 X X X
Start X - -
Stop inverse X - X
Qstopinverse X - X
DC brake inverse X - X
Coast inverse X X (HW)
3)
X
Reversing X - X
Jog X - -
Freeze output X - -
Freeze reference X - -
Speed up X - -
Speed down X - -
Preset reference on X - -
Preset reference LSB X - -
Preset reference MSB X - -
Catch up X - -
Slow down X - -
Relay01/relay04 X X X
Setup select LSB X X X
Setup select MSB X X X
Enable start forward X - X
Enable start reverse X - X
Speed Up/Setup Select LSB X X X
Speed Down/Setup Select MSB X X X
Latched Start X - -
Start Reverse X - X
1)" X" Means that the command is available
2) "-" Means that the command is NOT available
3) Terminal 37
MG.55.A7.02 - VLT is a registered Danfoss trademark
50