User manual

Illustration 6.31: Settings Backup & Restore
Item Description
Backup ‘Dumps’ the settings and the content of the production log of the particular
inverter to a file where the location and file name are specified by the user.
Browse Press 'Browse' to select an already saved settings file to be uploaded.
Upload & Set Pressing this button results in the settings being sent to the inverter in ques-
tion.
Note:
Note that this is an unrecoverable action. All earlier settings will be lost and cannot be re-
stored afterwards.
6.11.3.
Settings Report
[1] [Inverter]
This feature enables generation of a report listing the current functional safety parameters. This
report has to be signed by the customer, the service technician, and approved by the DNO.
For further instructions on how to change the functional safety settings of the inverter, refer to
the TripleLynx CN Reference Manual where a description of the complete procedure is given.
The service-related menus are described below. Note that some of the menus are visible on
plant level or inverter level only.
6.12.
Web Server
[0] [Plant]
6.12.1.
Admin
[0] [Plant]
Change the admin password for Web Server access here.
Illustration 6.32: Admin Master Password
For optimal security select a number-letter combination consisting of at least eight
characters for the password.
Changing the password here automatically changes the password for each inver-
ter.
6. Setup
54 L00410583-01_02