Inverter name The name of the inverter. At delivery, this name corresponds to the serial
number of the inverter. A maximum of 15 characters can be entered, see the
section
Supported Characters
for a complete list of the valid characters.
Inverter group name In order to group the inverters of the plant into different groups, a group
name is needed. A maximum of 15 characters can be used, see the section
Supported Characters
for a complete list of the valid characters.
To add more inverters to the same group just enter the same group name for
all inverters.
Inverters are delivered with the default group name
Group 1
.
Inverter is master This check box needs to be enabled if this particular inverter is the master
inverter in the network.
Enabling the master check box and pressing 'Save' generates an automatic
network scan and the 'Scan network' button will appear.
Per default the master check box is unchecked.
'Scan network' Press this button to scan for connected inverters.
The names of the inverters found will appear in the list. Check manually that
all connected inverters have been found. A network scan can be renewed at
any time. Newly found inverters will be added to the list, and inverters not
present in the network anymore will automatically be deleted from the list.
NOTE! The 'Scan network' button is only visible if the inverter is set up as
the master inverter.
Show list Pressing the 'Show list' button will open a pop-up window, which displays the
names of all the inverters currently connected to the master together with
their current status. Via the pop-up window it is possible to perform a quick
communication check from the master inverter to the other inverters. This is
done by pressing the 'Check communication' button.
NOTE! The 'Scan network' button is only visible if the inverter is set up as
the master inverter.
6.4.2.
Date and Time
[0] [Plant, Inverter]
This menu is visible in plant and inverter views only.
The date/time settings of the inverter can be changed here.
Illustration 6.12: Date and Time
Item
Description
Time The current time in the following format: hh:mm:ss
Be careful when changing the time settings of the inverter as changing the
time affects data which are already logged.
Setting the time back one hour will result in the existing data logged for the
last hour being overwritten.
Date The current date in the following format: dd-mm-yyyy.
Be careful when changing the date of the inverter as a date change affects
data which are already logged.
TimeZone Time zone in which the inverter is located.
Note:
The master inverter automatically ensures
identical date and time settings, and
adjustment to summer time throughout the network.