User manual
Note:
A correctly configured SMTP server and internet connection, IP and DNS server, are necessa-
ry for receiving e-mail messages from the inverter. To test the SMTP settings go to [Setup →
Messaging] on plant view, configure a recipient and press the 'Test Setup' button. Within a
few minutes, a test e-mail will be sent from the inverter.
Illustration 6.7: STMP Setup
Item
Description
SMTP server address Outbox server; this information can be requested from the Internet
provider (see below) or LAN administrator.
SMTP server port Here the server port used for the e-mail transfer can be changed. At
delivery it is configured to port 25.
Ask the network administrator before changing this value.
User name Service provider's user name. A maximum of 24 characters can be en-
tered.
Password Password assigned by the Internet service provider. For security rea-
sons, every password character is displayed as an asterisk (*). A max-
imum of 24 characters can be entered.
Retype password Retype the password.
E-mail sender address Sender's e-mail address used for authenticating the SMTP server. An
unknown sender address can cause e-mail delivery to fail.
User Authentication As authentication type exclusively SMTP authentication is supported!
If the authentication check box is checked, remember to enter the ac-
count information of the e-mail. This information will be forwarded by
the internet provider.
6. Setup
L00410583-01_02 33
6