User manual

Item Unit View Description
Plant
and
Group
Inverter
Overall plant sta-
tus
- x Red: Plant PR < 50 %, or:
Any inverter in the network
- in
fail safe
mode, or
- missing from the scan list, no contact with the master
Yellow: Any inverter in the network
- with PR < 70 %, or
- in
Connecting
or
Off grid
mode
Green: Plant PR ≥ 70 %, and
- all inverters with PR ≥ 70 %, and
- all inverters in
On grid
mode
x Red: Inverter PR < 50 %, or inverter has an error
Yellow: Inverter PR between 51 % and 70 %, or inver-
ter in
Connecting
mode
Green: No errors, and
- inverter PR ≥ 70 %, and
- inverter in
On grid
mode
Current production kW x x Real time energy production level
Yield today kWh x x Cumulative yield for the day
Total revenue Euro x x Cumulative revenue earned since initial startup
Total CO
2
saving kg x x Cumulative CO
2
saved since initial startup
Performance ratio % x x Real time performance ratio
Total yield kWh x x Cumulative yield since initial startup
Power limit adjust-
ment
% x Maximum power limit as % of nominal inverter AC output
rating
Note:
To calculate performance ratio PR, an irradiation sensor is required, see [Setup Calibra-
tion].
2.3.
Security Levels
Three predefined security levels filter user access to menus and options.
Security levels:
Level 0: End-user, no password is needed
Level 1: Installer / service technician
Level 2: Installer / service technician (extended).
When logged on to the Web Server as Admin, access is at security level 0. Subsequent user ac-
counts created provide access to a predefined subset of menus, according to user profile.
Define user profile at [Plant Setup Web Server Profiles]
Access to levels 1 and 2 requires a service logon, comprising a user ID and a password.
The service logon provides direct access to a specific security level for the duration of
the current day.
Obtain the service logon from Danfoss.
Enter the logon via the Web Server logon dialog.
When the service task is complete, log off at [Setup Security].
The Web Server automatically logs off the user after 10 minutes of inactivity.
Security levels are similar on the inverter display and the Web Server.
2. Getting Started