Technical data
Note:
For the TLX CN Pro and TLX CN Pro+ inverters the first start-up and check of settings can
also be performed via the integrated Web Server. For further details, refer to the Web Server
User Manual.
The inverter is shipped with a predefined set of settings for different grids. All grid specific limits
are stored in the inverter and must be selected at installation. It is always possible to see the
applied grid limits in the display. The inverter accounts for daylight saving automatically.
After installation, check all cables and then close the inverter.
Turn on AC at the mains switch.
When prompted by the display select language. This selection has no influence on the operating
parameters of the inverter and is not a grid code selection.
Illustration 8.4: Select Language
The language is set to Chinese at initial
start-up.
Illustration 8.5: Set Time
Set time as prompted by the display. Press
'OK' to select number. Press ‘
▲
’ to scroll up
through the numbers. Select by pressing
'OK'.
The clock is 24-hour format.
Note:
It is very important to set the time and date accurately as the inverter uses this for logging.
If a wrong time/date is accidentally set, correct it immediately in the set date and time menu
[Setup → Inverter details → Set date and time].
8. User Interface
72 L00410582-01_02
8