Technical data
Menu Structure - Setup - Continued
Display Functions Description
[0] Environment
*
[0] CO
2
emission factor: Value to be used for total CO
2
saved calculation
[0] 0.5 kg/kWh
[0] Remuneration per kWh: Value to be used for total revenue calculation
[0] 44.42 ct/kWh
[0] Yield start count: 1000 kWh
A value used as an offset from the current production val-
ue when calculating the yield.
[0] Communication setup
[0] RS485 setup
[0] Network: 15
[0] Subnet: 15
[0] Address: 255
[0] IP Setup
[0] IP config: Automatic
[0] IP address:
[0] 192.168.1.191
[0] Subnet mask:
[0] 255.255.255.0
[0] Default gateway:
[0] 192.168.1.1
[0] DNS server:
[0]123.123.123.123
[0] GPRS connection setup
[0] SIM PIN code: 0000 4-8 characters
[0] Access point name:
name Max. 24 characters
[0] User name:
user Max. 24 characters
[0] Password:
password Max. 24 characters
[0] Roaming: Disabled
[0] Data warehouse service
[0] Upload time (h:m): 14:55
[0] Start log upload Requires data from at least 10 min. of energy production
[0] D.W FTP server address:
www.inverterdata.com
[0] D.W server port: 65535
[0] FTP mode: Active
[0] D.W. server user name: Default serial number of the inverter
user User name for Data warehouse account, max. 20 chars.
[0] D.W server password
password Password for Data warehouse account, max 20 chars.
[0] Communication channel :
[0] Communication channel: GSM
Table 8.9: Setup - Continued
Menu Structure - Setup - Continued
Display Functions Description
[0] Logging
[0] Interval: 10 min The interval between each logging
[0] Logging capacity:
[0] 10 Days
[1] Delete event log
[1] Delete production log
[1] Delete irradiation log
[1] Delete data log
[0] Web Server
[0] Reset password Resets the password of the Web Server to its default value.
[0] Service
[1] Store settings Store inverter settings and data in the display of the inverter.
[1] Restore settings Restore all inverter settings and data stored in the display of the inverter.
[1] Replicate settings
Replicate all inverter settings to all other known inverters in the network. Only
visible if master mode is enabled.
[0] Security
[0] Password: 0000 Password
[0] Security level: 0 Current security level
[0] Log out Log out to security level 0
[0] Service logon Only to be used by authorised service personnel
[0] User name:
[0] user name
[0] Password:
[0] password
Table 8.10: Setup - Continued
8. User Interface
68 L00410582-01_02
8