Technical data
Three predefined security levels filter user access to menus and options.
Security levels:
• Level 0: End-user, no password is needed
• Level 1: Installer / service technician
• Level 2: Installer / service technician (extended).
When logged on to the Web Server as Admin, access is at security level 0. Subsequent user ac-
counts created provide access to a predefined subset of menus, according to user profile.
Define user profile at [Plant → Setup → Web Server → Profiles]
Access to levels 1 and 2 requires a service logon, comprising a user ID and a password.
• The service logon provides direct access to a specific security level for the duration of
the current day.
• Obtain the service logon from Danfoss.
• Enter the logon via the Web Server logon dialog.
•
When the service task is complete, log off at [Setup → Security].
• The Web Server automatically logs off the user after 10 minutes of inactivity.
Security levels are similar on the inverter display and the Web Server.
A security level grants access to all menu items at the same level as well as all menu items of a
lower security level.
Throughout the manual, a [0], [1] or [2] inserted after the menu item indicates the minimum
security level required for access.
8.1.1. View
Menu Structure - View
Parameter Description
[0] Mode: On grid Displays present inverter mode. See
Mode
definitions
[0] Prod. today: 12345 kWh Energy production today in kWh. Value from inverter or S0 energy-meter
[0] Power output: 12345 W Current output power in Watt
[0] [ --- utilization bar --- ] Shows level of inverter utilization as % of max. utilization
Table 8.1: View
8.1.2. View 2
Pressing F1 once more will result in the following screen being shown (see section on buttons
for more information):
Menu Structure - View 2
Parameter Description
[0] Grid mgmt:
Indicates whether or not any grid management measures are in effect.
Only visible if enabled by the current grid code.
[0] Performance ratio: 87 % Performance ratio is shown if irradiation sensor is available (local or master)
[0] Total CO
2
saved:123 T Lifetime CO
2
emission saved, calculated using configured value
[0] Total revenue: 234.5 Euro Lifetime revenue, calculated using configured value
Table 8.2: View 2
8. User Interface