Security levels:
Level 0: End-user, no password is needed
Level 1: Installer / service technician
Level 2: Installer / service technician (extended).
When logged on to the Web Server as Admin, access is at security level 0. Subsequent user ac-
counts created provide access to a predefined subset of menus, according to user profile.
Define user profile at [Plant Setup Web Server Profiles]
Access to levels 1 and 2 requires a service logon, comprising a user ID and a password.
The service logon provides direct access to a specific security level for the duration of
the current day.
Obtain the service logon from Danfoss.
Enter the logon via the Web Server logon dialog.
When the service task is complete, log off at [Setup Security].
The Web Server automatically logs off the user after 10 minutes of inactivity.
Security levels are similar on the inverter display and the Web Server.
A security level grants access to all menu items at the same level as well as all menu items of a
lower security level.
Throughout the manual, a [0], [1] or [2] inserted after the menu item indicates the minimum
security level required for access.
8.1.1. View
Menu Structure - View
Parameter Description
[0] Mode: On grid Displays present inverter mode. See
Mode
definitions
[0] Prod. today: 12345 kWh Energy production today in kWh. Value from inverter or S0 energy-meter
[0] Power output: 12345 W Current output power in Watt
[0] [ --- utilization bar --- ] Shows level of inverter utilization as % of max. utilization
Table 8.1: View
8.1.2. View 2
Pressing F1 once more will result in the following screen being shown (see section on buttons
for more information):
Menu Structure - View 2
Parameter Description
[0] Grid mgmt:
Indicates whether or not any grid management measures are in effect.
Only visible if enabled by the current grid code.
[0] Performance ratio: 87 % Performance ratio is shown if irradiation sensor is available (local or master)
[0] Total CO
2
saved:123 T Lifetime CO
2
emission saved, calculated using configured value
[0] Total revenue: 234.5 Euro Lifetime revenue, calculated using configured value
Table 8.2: View 2