Datasheet
Data Sheet SONOMETER
TM
2000 – Ultrasonic heat meter
Ordering
AAA BB - C D E F G H - I J K L M - NN O
O - verification
0 without approval mark
1 compliant according to national regulations
3 compliant to MID. No letter of conformity
4
compliant to MID. With letter of conformity
(inital verification)
GH - interface modules
modules slot 1
not relevant / no module in slot 1 0
M-Bus module A
RS-232 module B
Real Data radio module C
Module for 2 additional pulse inputs D
RS232 adapter for radio E
modules slot 2
not relevant / no module in slot 2 0
Module for volume and energy pulse outputs K
Module for 2 additional pulse inputs L
Module for 2 pulse inputs + 1 pulse output M
(standard setting for pulse input modules: 100 l / pulse
standard setting for pulse output modules: energy and volume, pulse value is the
last digit in the display)
J - temperature sensors (pair)
0 without sensors
C Pt 100 / ø 5.2 mm / 2 m cable
E Pt 500 / ø 5.2 mm / 2 m cable
F Pt 500 / ø 5.2 mm / 3 m cable
G Pt 500 / ø 5.2 mm / 5 m cable
H Pt 500 / ø 5.2 mm / 10 m cable
N Pt 500 / ø 5.2 mm / 2 m cable, MID
O Pt 500 / ø 5.2 mm / 3 m cable, MID
P Pt 500 / ø 5.2 mm / 5 m cable, MID
Q Pt 500 / ø 5.2 mm / 10 m cable, MID
I Pt 500 / ø 6.0 mm / 1.5 m cable
J Pt 500 / ø 6.0 mm / 3 m cable
K Pt 500 / ø 6.0 mm / 5 m cable
L Pt 500 / ø 6.0 mm / 10 m cable
M Pt 500 / ø 6.0 mm / 20 m cable (no approval)
T Pt 500 / ø 6.0 mm / 2 m cable, MID
U Pt 500 / ø 6.0 mm / 3 m cable, MID
L - accessories / pocket
0 without
for ø 5.2 mm temperature sensors (pair
1
)
A brass-pockets, 34 mm DN 15-32
B brass-pockets, 50 mm DN 40-65
D brass-pockets, 85 mm DN 80-125
E brass-pockets, 120 mm DN 150-200
F brass-pockets, 35 mm, MID
3
DN 15-32
G brass-pockets, 52 mm, MID DN 40-65
H brass-pockets, 85 mm, MID DN 80-125
I brass-pockets, 120 mm, MID DN 150-200
for ø 6.0 mm temperature sensors (pair)
K brass-pockets, 40 mm DN 25-65
L brass-pockets, 85 mm DN 80-125
M brass-pockets, 120 mm DN 150-200
N stainless steel-pockets, 85 mm DN 80-125
O stainless steel-pockets, 120 mm DN 150-200
P stainless steel-pockets, 155 mm DN 200-250
Q stainless steel-pockets, 210 mm DN 300
V brass-pockets, 40 mm MID DN 25-65
W brass-pockets, 85 mm MID DN 80-125
X brass-pockets, 120 mm MID DN 150-200
Y stainless steel-pockets, 85 mm MID DN 80-125
Z stainless steel-pockets, 120 mm MID DN 150-200
1 stainless steel-pockets, 155 mm MID DN 200-250
2 stainless steel-pockets, 210 mm MID DN 300
Accessories
R ball valve DN 15 - ½” for direct sensor
2
(1 piece)
S ball valve DN 20 - ¾” for direct sensor
2
(1 piece)
T ball valve DN 25 - 1” for direct sensor
2
(1 piece)
U adapter for mounting direct sensor R½” M 10x1
2
M - connections (sets)
0 without
1 screwing set R ½” x G ¾ B
2 screwing set R ¾” x G 1 B
3 screwing set R 1” x G 1¼ B
4 screwing set R 1½” x G 2 B
5 weld-on tail pieces x G 1¼ B
6 weld-on tail pieces x G 2 B
C - pressure
not relevant 0
PN 16 C
PN 25
1
D
1
Flange versions must be PN 25
NN - country code
00 Neutral code with docs in English
AT Austria
BA Bosnia
BG Bulgaria
CN China
DK Denmark
EE Estonia
HR Croatia
CZ Czech Republic
DE Germany
GB United Kingdom
IE Ireland
IT Italy
KZ Kazakhstan
LV Latvia
LT Lithuania
MD Moldova
MK Macedonia
PL Poland
RO Romania
RU Russia
CS Serbia
SK Slovak Republic
SI Slovenia
TR Turkey
UA Ukraine
XM Montenegro
1
versions with one sensor pocket on request
2
not possible for ø 6.0 mm sensors
3
max temperature: 105°C
1
only for ø 5.2 mm sensors
- - -
AAA - application
accessories only
1
000
only temperature sensors
1
4TS
heat meter for heating 2HE
heat meter for cooling (only with SONO 2500CT) 2CO
heat meter for heating/cooling (only with SONO 2500 CT) 2HC
only flow sensor for heating 15H
for energy meter for cooling (heating/cooling) up to qp 25 m³/h use SONOMETER™1000
1
prices valid in the Accessories list
F - power supply
not relevant / with external power supply
1
0
battery 3.0 V DC (C-cell)
2
1
battery 3.6 V DC (D-cell)
2 3
2
mains unit 230 V AC
2
3
mains unit 24 V AC
2
4
1
only for flow sensor
2
only for combination Infocal 6 + SONO 1500 CT
3
only for combination Infocal 6 + SONO 2500 CT
BB - (for) flow sensor (type SONO 1500 CT)
not relevant / no flow sensor 00
qp 0.6 m³/h / 110 mm thread / DN 15 / G¾B / 1 litre / pulse 1A
qp 0.6 m³/h / 130 mm thread / DN 20 / G1B / 1 litre / pulse 1B
qp 0.6 m³/h / 190 mm thread / DN 20 / G1B / 1 litre / pulse 1C
qp 1.0 m³/h / 110 mm thread / DN 15 / G¾B / 1 litre / pulse 1D
qp 1.0 m³/h / 130 mm thread / DN 20 / G1B / 1 litre / pulse 1E
qp 1.0 m³/h / 190 mm thread / DN 20 / G1B / 1 litre / pulse 1F
qp 1.5 m³/h / 110 mm thread / DN 15 / G¾B / 1 litre / pulse 1G
qp 1.5 m³/h / 130 mm thread / DN 20 / G1B / 1 litre / pulse 1H
qp 1.5 m³/h / 190 mm thread / DN 20 / G1B / 1 litre / pulse 1I
qp 2.5 m³/h / 130 mm thread / DN 20 / G1B / 1 litre / pulse 1J
qp 2.5 m³/h / 190 mm thread / DN 20 / G1B / 1 litre / pulse 1K
qp 3.5 m³/h / 260 mm thread / DN 25 / G1¼B / 10 litre / pulse 1L
qp 6 m³/h / 260 mm thread / DN 25 / G1¼B / 10 litre / pulse 1M
qp 10 m³/h / 300 mm thread / DN 40 / G2B 1N
qp 0.6 m³/h / 190 mm flange DN 20 / 1 litre / pulse
1
2A
qp 1.0 m³/h / 190 mm flange DN 20 / 1 litre / pulse
1
2B
qp 1.5 m³/h / 190 mm flange DN 20 / 1 litre / pulse
1
2C
qp 2.5 m³/h / 190 mm flange DN 20 / 1 litre / pulse
1
2D
qp 3.5 m³/h / 260 mm flange DN 25 / 10 litre / pulse
1
2E
qp 3.5 m³/h / 260 mm flange DN 32 / 10 litre / pulse
1
2F
qp 6 m³/h / 260 mm flange DN 25 / 10 litre / pulse
1
2G
qp 6 m³/h / 260 mm flange DN 32 / 10 litre / pulse
1
2H
qp 10 m³/h / 300 mm flange / DN 40
1
2I
qp 15 m³/h / 270 mm flange / DN 50
1
2J
qp 25 m³/h / 300 mm flange / DN 65
1
2K
1
only PN 25 possible
BB - (for) flow sensor (type SONO 2500 CT)
1
qp 40 m³/h / 300 mm flange DN 80 / 100 litre / pulse 2Z
1
only PN 25 possible
D - flow sensor cable
not relevant 0
2.5 m (standard) A
5 m B
10 m C
E - installation
not relevant 0
forward F
return R
I - energy units
0 not relevant / only flow sensor
A kWh (without digit after comma) only for 0.6 - 6 m³/h
B MWh (with 1 digit after comma)
C MWh (with 2 digits after comma)
D MWh (with 3 digits after comma) only for 0.6 - 6 m³/h
E GJ (with 1 digit after comma)
F GJ (with 2 digits after comma)
G GJ (with 3 digits after comma) only for 0.6 - 6 m³/h
H Gcal (with 1 digit after comma)
I Gcal (with 2 digits after comma)
J Gcal (with 3 digits after comma) only for 0.6 - 6 m³/h
K MBtu (with 1 digit after comma)
L MBtu (with 2 digits after comma)
M MBtu (with 3 digits after comma) only for 0.6 - 6 m³/h
K - temperature sensor mounting
0 not relevant
1
qp 0.6 - 2.5: Prep. for mounting one sensor in flow sensor
1
qp 3.5 - 25: indirect mounting (2 free sensors)
2 qp 3.5 - 10: Prep. for mounting one sensor in flow sensor
1
3
DH-SMT/PL
VD.SH.A3.02 © Danfoss 08/2009