Operating instructions and installation of heat pumps Hotjet Hotjet CZ s.r.o. ! ! ! ! Operating instructions and installation of heat pumps Hotjet (3.
Contents: 1.User instructions! 3 1.1.General information! 3 1.1.1.System description!............................................................................................................................................................................................3 1.1.2.Warning!.............................................................................................................................................................................................................4 1.2.
1. User instructions 1.1. General information Congratulations on your purchase of heat pump Hotjet. Get familiar with these instructions to get the best use and a long service from the pump. The heat pump is a compact unit designed for heating water for hot service water and for heating. The source of heat is the external air, of which heat is transferred to water in an exchanger. The heat pump is a long service life and a very safe product. We wish you a trouble-free operation and a lot of thermal comfort.
Principle of operation of heat pumps: 1.1.2. Warning BEWARE: The device contains electrical components under tension. The device may be opened only by a person with relevant electrical qualification. Risk of electric shock. ! The power supply circuit of the heat pump must comply with standard ČSN 33 2000 ! We recommend installation of an 30mA tripping current earth leakage relay (ČSN EN 60335-2-40 ed.) and a lockable main switch.
be exposed to high temperatures and the danger of perforation. ! Hot water above 52° C temperature may cause serious burns or death by scalding. ! Never remove or cover any of the markings, labels and warnings placed on the heat pump, as these should be visible at all times. Replace the damaged ones with new ones. ! The control panel must be out of reach of children. ! Be careful to avoid injuries on sharper edges and projections.
2. Installation Instructions This part of the documentation is intended for qualified installation and service staff as an assistant for proper installation, operation and maintenance of the heat pump HOTJET. Read it carefully, failure to comply with instructions may lead to malfunctioning of the heat pump, damage to property, scalding or electrocution injuries. 2.1. Handling refrigerant • Heat pump refrigeration circuit includes Hotjet filled with refrigerant.
2.2. Parts of heat pump 2.2.1.
Position Description Position 9 Compressor 22 Description Pallet exchanger 10 Expansion valve 23 Darin Valve 11 Heating of condenser plate 24 Heat exchanger 12 Condenser plate 25 Filter dryer 13 Supporting base unit 26 Fan frame 2.2.2.
Position Position Description Description 4 Entry heating water heat pump 16 Sight 5 Foldable cover wiring 17 Expansion valve 6 Heat pump controller 18 Expansion valve 7 Heat exchanger 19 Refrigerant separator 8 Evaporator 20 Drain valves 9 High pressure controls and low pressure 21 1st isolation 10 Filling valves on the intake of compressor displacement 22 2nd isolation 11 Penetrations for electrical installations from the right side 23 Cover face 12 Spring-loaded base
Position Description Position Description 1 Isloation 11 Heat exchanger 2 Fan Cover 12 Sight 3 Fan 13 Flow switch 4 Fan frame 14 Expansion valve 5 Refrigerant separator 15 Electric box 6 Spring-loaded base unit of cooling circuit on silent blocks 16 Evaporator 7 Compressor 17 Filter dryer 8 Legs 18 Fan palte 9 Filling valves on the intake of compressor displacement 19 Plate exchanger 10 High pressure controls and low pressure 2.3. Location and connection 2.3.1.
32+/(' & % 32+/(' $ ' 02'(/ $ $ % & % $ 32+/(' % 3RO Ā & 1i]HY NRPSRQHQWX .U\Ft GĢHYďQQi GHVND [ [ 'ĢHYR $6. 'ĢHYR $6.
2.3.2.Space for installation model 300mm The heat pump is designed for installation in the house - utility rooms, cellar, garage, land, and the like. Installing the indoor unit on the construction over 50% humidity can cause condensation on the cover of the pump or air-duct. For service approach to be followed by a minimum distance diagram: Connected Heating System 600mm Electrical outlets Service access 300mm • 2.3.3.
2.3.4.Model , base and pedestal • Place the heat pump on a solid surface, which preferably consists of a concrete base, concrete footing or paving • It is not advisable to place the heat pumps on larger areas – e.g. parking lots, pavements - as these do not muffle noise well. • Install the heat pump at least 0,3 m above the surface.
Detail of a typical heat pump connected to the heating system or the equalizing reservoir. Position Description 1 Heat pump 2 Expansion tank 7 Flexible hose 6 Flow electric boiler PV Safety valve KK Ball valve Inlet Air suck Outlet Air Exhaust 2.3.5.
2.4. Connecting the power supply: The heat pump is available in these designs and regulating the location of wiring: Code Item Description Hotjet i - RZ1 RZ1 Internal electronics installation. Place for the management of the heat pump.There is no room for placement AVS37, therefore suitable for combination with QAA78. RVS41 AVS37 cable AVS-RVS Compressor contractor fan relay 3f terminal Circuit breaker control All electronics and controller in an external cabinet.
Code Item Description RZ2 Option-country body of water for the location of electrical panel and AVS37 HP. RVS41 AVS37 cablet AVS-RVS Compressor contactor terminal switch Circuit breaker control Compressor circuit breaker RZ3 Combined installation of the internal distribution boards and extension of space for the installation of circuit breakers and contactors bivalence, auxiliary relay, etc.
2.4.1.Hotjet w - variation with displacement and RZ2 & RZ3 • Dismount the front plate • Loosen the locking screw flip cover from the underside of the lid carrier • Pull the cover • 400V power cable ready to install WAGO terminals. 2.4.2. Hotjet w - variant without body After removal of the front cover, remove the cover plate Switchboard 400V power cable ready to install WAGO terminals. Hotjet CZ s.r.o. ! ! ! ! Operating instructions and installation of heat pumps Hotjet (3.
2.4.3. Hotjet s -indoor unit Dismantling and connect the power cord is the same as Hotjet w 2.4.4. Hotjet s - connection with the internal unit Unscrew the top cover with 4 screws, 2 screws from the front side and 2 screws at the rear, as shown Remove the lid and the side cover plate U-shaped lift up, because the bottom of the "sit" on the pins at the bottom of the machine. The upper part is located in the distribution wire connection terminal. See diagram electrical schematics. Hotjet CZ s.r.
3. Technical data of heat pumps Hotjet 3.1. Technical data of heat pump Hotjet “ i “ • The condensate drainpipe can be carried out into sewerage Source of heat: suction air Installation position garage, cellar, workroom, utility room, farm building Characteristics External part of installation: there is none, just holes in the wall and covering grate/shutter on the facade New generation of heat pumps hotjet “i” is highly functional while the price is still unbeatable.
• • May be charged equithermally May be charged, so-called, forcedly, when it is charged up to the required temperature. Startup of this function may be linked to switching electrical energy rates, certain time or it can be controlled by external command. One of the advantages is the possibility of “collection” of heat when the conditions are better. For example the air temperature is higher.
3.1.1.Technical data MODEL HOTJET 8i Performance data HOTJET 11i HOTJET 15i Power output / Power input / COP A7/W35 7,8 / 2,04 / 3,8 9.3 / 2.45 / 3.8 10.8 / 2.79 / 3.8 A2/W35 7,2 / 2,01 / 3,6 8.6 / 2.39 / 3.6 10.1 / 2.76 / 3.6 A7/W45 7,4 / 2,46 / 3,0 8.8 / 2.93 / 3.0 10.3 / 3.39 / 3.0 A2/W45 6,6 / 2,46 / 2,7 8.0 / 2.96 / 3.0 9.3 / 3.44 / 2.
MODEL HOTJET 8i HOTJET 11i HOTJET 15i 1/N/PE ~230 V, 50 Hz Electrical connection Power supply - 1 phase 230V / 1 / 50 Hz Compressor Copeland scroll Service current [A] Starting current [A] Maximum service current [A] Compressor protection [A] 15 A 15A 914 A 61 A 84 A 84A 20 A 20 A 20 A 25 B 32 B 32B Compressor supply line (n x mm2) Noise level 3x4 Sound power Lw [dB(A)] < 50 Sound pressure Lp [dB(A)] < 37 Equipment Control electronics Siemens RVS41 Operator panel AVS37 on the dev
E E E směr přístupu k elektru a chladícímu okruhu E E 3.1.2.Drawing heat pump Hotjet “ i “ Hotjet CZ s.r.o. ! ! ! ! Operating instructions and installation of heat pumps Hotjet (3.
Hotjet CZ s.r.o. ! Operating instructions and installation of heat pumps Hotjet (3.08/2010/01) ! ! ! 24 z 46 ' & % $ 95$71É 27231É 92'$ 91Ď-äÌ =É9,7 .RQWURO .UHVOLO )LUPD 3OLVND -PpQR +27-(7 V U R 967831Ì 27231É 92'$ 91Ď-äÌ =É9,7 3RGSLV 2'92' .
3.2.
Heating system: Purely equithermal control (by the external temperature only) control according to space temperature Equithermal coupled with space control One regulator manages up to two mixing heat circuits and one pump circuit Each heating circuits can be controlled fully independently with the use of its own space unit The existing ON/OFF switching mode thermostats can be used Addition of more heating circuits with the use of zone regulators RVS Integration with a h
3.2.1.
MODEL 8ask Noise level Sound power level dB(A) 11ask 15ask 18ask 21ask 61 57 Sound pressure level at 1 m dB(A) Equipment Control electronics Siemens RVS41 Operator panel AVS37 on the device Wireless device QAA78 External switchboard with electronics Soft start unit Condensate pump yes (optionally RVS61) yes optional optional (the whole wiring system is housed in external switchboard) optionally Danfoss optional *) Values as A2/W35 mean: intake air temperature is 2 ° C, outlet water temperature fro
Výkonové diagramy tepelných čerpadel řady ASK pro topnou vodu 35°C 23 Topný výkon [kW] Elektrický příkon (kW] 22 21ask 20 18ask 18 16 15ask 14 11ask 12 8ask 10 8 6 21ask 18ask 15ask 11ask 8ask 4 2 0 -22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 21 Teplota nasávaného vzduchu [°C] Výkonové diagramy tepelných čerpadel řady ASK pro topnou vodu 45°C 23 Topný výkon [kW] Elektrický příkon (kW] 21ask 22 20 18ask 18 16 15ask 14 11ask 12 8ask 10
ké údaje HotjTechnické údaje Hotjet s Operating instructions and installation of heat pumps Hotjet (3.08/2010/01) ! ! ! ' & % $ 32+/(' ' 3ġ,32-29$&Ì 91Ď-äÌ =É9,7 32+/(' & 32+/(' % 6752-1Ì ÿÉ67 9ë)8.29É 675$1$ /$0(/29ë 9ë'8&+ = 9ë3$51Ì.8 32+/(' $ .RQWURO .
3.3. Technical data of heat pump Hotjet “ s “ Installation position Indoor unit: any place inside the building – technical room, basement, garage... Outdoor part of the system: ground, wall, roof Characteristics Heat source: air New models of air to water heat pumps of the split type distinguish by a favourable price with outstanding parameters. The split installation enables flexible utilisation of the heat pump in various types of buildings.
temperature. Start-up of the function can be related to the power supply tariffs switch-over, either via time or external command. The advantage consists in a possibility to accumulate heat under better conditions, i. e. when the air temperature is higher. Bivalent source: Supports electrical cartridges in flow or tank Supports exernal sources (existing gas, electrical or other boilers) Three-level or single-level bivalence control Heating system: Solely equithermal control (acc.
3.3.1.
MODEL 8s 11s 15s 18s 22S 35S 50S Starting current [A] 18 20 23 36 36.
Výkonové diagramy tepelných čerpadel řady "Hotjet s" pro topnou vodu 35°C 22 Topný výkon [kW] Elektrický příkon (kW] 23 21s 22 18s 20 18 16 15s 14 11s 12 8s 10 8 6 21s 18s 15s 11s 8s 4 2 0 -22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 Teplota nasávaného vzduchu [°C] 6 8 10 12 14 16 18 21 Výkonové diagramy tepelných čerpadel řady "Hotjet s" pro topnou vodu 45°C 23 Topný výkon [kW] Elektrický příkon (kW] 22 21s 20 18s 18 16 15s 14 11s 12 8s 10 8 6 21s 1
Výkonové diagramy tepelných čerpadel řady "Hotjet s" pro topnou vodu 35°C 50 50s 48 Topný výkon [kW] Elektrický příkon (kW] 46 44 42 40 38 35s 36 34 32 30 28 26 24 22 20 18 16 14 12 10 50s 8 35s 6 4 0 -22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 21 Teplota nasávaného vzduchu [°C] Výkonové diagramy tepelných čerpadel řady "Hotjet s" pro topnou vodu 45°C 50 Topný výkon [kW] Elektrický příkon (kW] 50s 48 46 44 42 40 38 35s 36 34 32 30 28 26 24 22 20 18
3.3.2.Drawing Hotjet "S" - indoor unit ! ! ! % $ Operating instructions and installation of heat pumps Hotjet (3.08/2010/01) ' & 96783 352 92',ÿ( 2' 29/É'É1Ì $ .2081,.$&( 02æ1267 /(9e+2 1(%2 35$9e+2 3ġ,32-(1Ì 92',ÿÔ 96783 352 92',ÿ( 6,/29e (1(5*,( Hotjet CZ s.r.o. ! 37 z 46 )LUPD .RQWU .
! ! ! Operating instructions and installation of heat pumps Hotjet (3.08/2010/01) D C B D 1 857 1107 1241 1271 2 STAVĚCÍ NOŽKA REKTIFIKACE +-20 mm 3 Kontrol. Kreslil Jméno Pliska 1273 1296 POHLED Z HORA Podpis 22.5.09 Datum Hmotnost: 13.67 Materiál: Sériová v"roba Typ dokumentace: V!PARNÍK Odstranit otřepy a ostré hrany 5 Měřítko: Číslo v"kresu: List: C B A A4 SPLIT v"parník 00813 S ROZMĚROVÁ SESTAVA Název v"kresu: MATERIÁL: NEREZOV! PLECH Revize: V!STUP PLYN.
3.4. Technical data of heat pump Hotjet “ w “ • High technology with top electronics at reasonable price.
Divalent source: • Support of electric cartridges in the flow or reservoir • Support of external sources (current gas, electric and other boilers) • Three-stage or one-stage divalence control Heating system: • Solely equithermal control (according to the outdoor temperature only) • Control according to the spatial temperature • Equithermal control with a linkage to space (room) • One regulator can maintain 2 mixing heating circuits and one pump circuit • Each heating circuit may be controlled absolutely ind
3.4.1.
MODEL Equipment 9W 12W 16W 20W 33W 50W Control electronics Siemens RVS41 (optionally RVS61) Phase monitoring order, phase loss and phase imbalance (RVS41 externally, RVS61 internally) Operator panel yes AVS37 on the device Wireless device optional QAA78 External switchboard Optional (the whole wiring system is housed in external switchboard) with electronics Soft start unit optionally Danfoss (Siemens) Integration into Up to 16 heat pumps or mixed sources are supported cascade Bivalence (back-up powe
3.4.2.Installation Hotjet “W” Hotjet CZ s.r.o. ! ! ! ! Operating instructions and installation of heat pumps Hotjet (3.
Hotjet CZ s.r.o. ! ! ! ! Operating instructions and installation of heat pumps Hotjet (3.
4. EC declaration of conformity to the heat pump Manufacturer: HOTJET CZ s.r.o. M.Kopeckého 675 708 00 Ostrava-Poruba Czech Republic http://www.hotjet.eu Hereby confirm that the design and construction of the product(s) listed below, in the version(s) placed on the market by us, conform to the relevant requirements of the applicable EC directives. This declaration becomes invalidated if any modifications are made to the product(s) without our prior authorization.
5. GUARANTEE CERTIFICATE FOR THE HEAT PUMP Type (model) designa2on: .......................................................................................... Compressor serial number: .......................................................................................... Date of sale: ...............................................................................