ORT-01 Electronic modulating room thermostat for OpenTherm appliances Installation and User Guide Danfoss Heating
Index Index GB Specification..................................................................................... 3-4 Positioning and installation .............................................................5 Wiring................................................................................................ 6-7 Mounting..............................................................................................8 Locking & Limiting........................................................................
Specification Code Number Temperature range 087N774300 8-30°C Maximum ambient temperature 45°C Control type P+I OpenTherm software version 2.
Specification GB NL Specification ERP Class The products represented within this document are classified according to, and allow completion of, the Energy Related Product (ErP) Directive System Package fiche and the ErP system data label. ErP Labelling obligation is applicable from 26th September 2015.
(5FT) ORT-01 GB NL Positioning and Installation Positioning and Installation 5
Wiring GB NL Wiring 6 1. For surface mounted wiring, cutouts are provided on the backplate to enable correct positioning of the cable. 2. For recessed wiring, cabling can be connected as in diagram 2.
ORT-01 A B OpenTherm connections in ORT- 01 Wiring GB NL Wires can be crossed O O OpenTherm connections in boiler Important - To avoid damage to Boiler and Thermostat, connect only to OpenTherm connections on boiler, do not connect to any other power source.
Mounting GB NL Mounting 8
Locking and Limiting Important Note: If Holiday Function 1. is required DO NOT adjust lower limit. Locking and Limiting GB NL 1. Before removing dial, turn until setting 10 aligns with reference mark on front case. 2. Remove dial, lock or limit as required (see note below). 3. Replace dial, ensuring setting 10 aligns with reference mark on case. 2.
User Instructions GB NL User Instructions Unlike normal room thermostats, the ORT-01 Setting Dial varies the heat output of the Opentherm condensing boiler to which it is connected. This adds significantly to the boiler efficiency by ensuring that the Indicator boiler keeps in economical condensing mode whenever possible.
Settings GB NL Room Temperature Setting 10 – 30°C: Set dial to required room temperature, domestic hot water store in boiler is kept hot*. User Instructions Holiday Setting : Controls room temperature at 8°C, (frost setting), domestic hot water store in boiler is turned off. *(This feature is dependant upon boiler type). Indication Start-Up: When boiler is first turned on the LED will flash for 20 seconds. Normal Operation: LED will be lit whenever the boiler is firing.
Technische Specificaties NL Technische Specificaties Technische Specificaties Bestelnummer Temperatuurbereik 8 - 30°C Maximale omgevingstemperatuur 45°C Regelprincipe P+I OpenTherm Protocol 2.
Technische Specificaties De in dit document beschreven producten zijn geclassificeerd overeenkomstig de richtlijn voor energiegerelateerde producten (ErP) en stellen u in staat om zowel het datablad voor het systeempakket als het ErP-systeemlabel aan te maken. De ErP-labelverplichting gaat in op 26 september 2015.
Positionering / Installatie NL Positionering / Installatie 14 (5FT) ORT-01
Bedrading For surface mounted wiring, cutouts are provided on the backplate to enable correct positioning of the cable. 2. For recessed wiring, cabling can be connected as in diagram 2. Bedrading NL 1.
Bedrading NL Bedrading A B OpenTherm OpenTherm connections aansluiting in in ORT- 01 ORT-01 Wires can be Draden crossed mogen gewisseld worden O 16 O OpenTherm OpenTherm connections in aansluiting in boiler ketel Belangrijk - Om schade aan ketel en thermostaat te voorkomen dient de thermostaat alleen op de OpenTherm aansluiting van de ketel te worden aangesloten.
NL Montage Montage 17
Blokkeren & Begrenzen NL Blokkeren & Begrenzen 1. Draai de instelknop op stand 10. 2. Verwijder de instelknop en blokkeer of begrens naar behoefte ( zie onderstaand schema). 3. Plaats de instelknop op stand 10 weer terug. Let op: Stel geen minimum begrenzing in als de Vakantie Stand nodig is. 1. 18 2.
Gebruikers handleiding NL Anders dan bij normale aan/uit thermostaten regelt de ORTInstelknop 01 de warmteafgifte van de OpenTherm ketel waarop hij is aangesloten. Dit draagt in hoge mate bij aan het ketelrendement door te zorgen dat de ketel zo lang LED Indicator mogelijk in HR (condenserend) bedrijf werkt. Dagelijks gebruik is zeer eenvoudig door de instelknop van de thermostaat simpelweg op de gewenste temperatuur in te stellen.
NL Instellingen Instellingen Ruimtetemperatuur instelling 10 – 30°C: Zet de instelknop op de gewenste ruimtetemperatuur, tapwater voorraad wordt op temperatuur gehouden*. Vakantiestand : Regelt de ruimtetemperatuur op 8°C, (vorst beveiliging), warm tapwater uitgeschakeld*. *(Deze funktie is afhankelijk van het keteltype). LED-indicator Opstarten: Na het inschakelen van de voedingsspanning van de ketel knippert de LED gedurende 20 seconden. Normaal bedrijf: LED is aan wanneer de ketel brandt.
www.heating.danfoss.co.