User's Guide

© Danfoss | DCS | 2021.01 4
The device PROCTO gives the possibility to perform the block command and to grasp
diagnostic information only in conjunction with an electronic thermostat.
The current version of the PROCTO includes the compatibility with the
Danfoss ERC 111 and 112 thermostats.
For other models and brands please contact your commercial contact.
3. Compatibility
The PROCTO requires two connections, one for the power supply, the other with the electro
nic thermostat.
4. Connections and wires
The power supply can be shared with the electronic thermostat: the PROCTO device does not require
additional power adapter.
Note: All the cables have to be assembled by the Cooler Manufacturer following the instructions here below.
For the POWER SUPPLY connector of the OCTO, either two standard fast-on connectors or one
connector with screw terminal can be used. Fig. 5 on the right, illustrates the Lumberg 3611 02 K1, an
easy plug connector with lift clamp and protection against misplacing and fast assembling. Neither
the standard fast-on connectors nor the easy plug connector are included in the OCTO package.
Note: If the power supply cable is not double insulated, it has to be physically separated from the
COMM cable.
Standard fast-on
Easy plug double fast-on
(for indirect mating)
Fig. 5: Two possible PROCTO terminations for the power supply cable.
The one on the right is the Lumberg 3611 02 K1.
Fig. 4: The connection schema
C
Electronic Thermostat
PR-OCTO
100 – 240 V AC ~
COMM Cable
This distance has to be at least 5 cm in case
the power supply is not double insulated
Danfoss
80G435