Technical data

Adjustment to the radiator
The device can be adjusted to the room size. Three room sizes are known. The default size is P1. To
change the assumed room size press (p) for 3 seconds to enter management mode (M in display). Press (v)
until a 'P' is displayed in the LCD display. Hit the (o) button. Now select 1, 2 or 3 using the arrow keys and
exit with (o).
Removal
To remove the thermostat, insert an appropriate tool in the hole in the thermostat's battery chamber (see
illustration). Keeping the tool in position, turn the entire thermostat anticlockwise until it is completely
unscrewed.
Behavior within the Z-Wave network
I
On factory default the device does not belong to any Z-Wave network. The device needs to join an
existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the
primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion
mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or
exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave
the network. Leaving the network - i.e. being excluded - sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network.
Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to
be reset first.
Click on the middle button will confirm inclusion or exclusion and wakeup the device for wireless
communication. A long push for 3 seconds on the middle buttons enters and leaves the management mode
indicated by a 'M'.
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 3