Installation guide

Outdoor unit Heat pump
211
213
386
387
125,
N/220
127
PE
220/N
211
213
283
386
387
125
1
2
3
4
6
5
1 Fan high speed
2 Fan low speed
3 Defrost sensor
4 Accessories
5 Neutral
6 Heating, drip tray
1. Route the power cable through the opening in the lower back panel of the heat pump to the terminal blocks.
2.
Connect the power cable to the terminal block.
Connect component plug
The delivery package includes three component plugs for the outdoor unit. These plugs are stored in a plastic bag attached at the elec-
trical cabinet inside the outdoor unit.
1. Select one of the following component plugs depending on the heat pump size:
Component plug Heat pump size
710 6kW or 8kW
560 10kW
390 12kW
R3
0-10V
R2
R1
K4
2. Mount the correct component plug in position R3 in the terminal block.
6.6 Connect temperature sensor hot water
Sensor for hot water and hot water peak from external water heater is connected in the following way to DHP-L.
311
312
325
326
54
55
54 Hot water sensor
55 Hot water top sensor
Danfoss Heating Solutions VMGFQ202
43
Installation Guide Domestic heat pumps