Installation guide
3.3.4 Removing the front cover
1
2
3
Do not damage the electrical wiring for the display when the front cover
is removed!
1. Press against the front cover and turn the catch 90° degrees anti-clockwise to release the front
cover.
2. Tilt the front cover outwards.
3. Lift the front cover upwards to remove it from the heat pump.
3.4 Setting-up the outdoor unit
3.4.1 Recommended location
When positioning the outdoor unit, note the following:
When the outdoor unit is defrosting, water will drip straight down under the unit. The area around the out-
door unit must therefore be properly drained in order to take the water (approximately 6 litres per defrost).
The outdoor unit must be positioned on a secure base such as wooden sleepers, paving slabs or cast footings.
N
The outdoor unit does not have to be positioned in any specific direction.
N
Position the outdoor unit to reduce noise disturbance in your own home as well as to any neighbours.
Danfoss Heating Solutions VMGFQ202
13
Installation Guide Domestic heat pumps