Connection
The stand shown in the image is an accessory.
1 Supply line heating system, AX 6, 8, 10: 22 Cu,
AX 12: 28 Cu
2 Return line heating system, AX 6, 8, 10: 22 Cu,
AX 12: 28 Cu
Indoor unit
Components
The component
image below shows
diagrammatically how
the heat pump looks
inside. There may be
differences between
different versions.
1 Fan
2 Operating pressostat
3 High pressure pressostat
4 Low pressure pressostat
5 2-way expansion valve
6 Drying filter
7 Compressor
1
8
9
7
10
12
13
11
4
6
5
3
2
1
8
9
7
10
12
13
11
4
6
5
3
2
8 Air heat exchanger
9 Electrical cabinet
10 Condenser
11 Four way valve
12 Heating system supply line
13 Return line heating system
602
380
212
205
602
380
212
205
DHP-AX
6 8 10 12
Refrigerant Type R407C R407C R407C R407C
Amount kg 1.6 1.6 2.5 2.7
Test pressure MPa 3.4 3.4 3.4 3.4
Design pressure MPa 3.1 3.1 3.1 3.1
Compressor Type Scroll Scroll Scroll Scroll
Oil POE POE POE POE
Electrical data
3-N~50Hz
Main supply Volt 400 400 400 400
Rated power, compressor kW 2.0 2.3 3.6 4.4
Rated power, fan kW 0.3 0.3 0.3 0.3
Start current A 16 17 22 22
Circuit breaker A 10 10 16 16
Electrical data
1-N~50Hz
Main supply Volt 230 230 230 230
Rated power, compressor kW 3.3 4.2 5.4 5.7
Rated power, fan kW 0.3 0.3 0.3 0.3
Start current A 56 76 97 108
Circuit breaker A 20 20 25 32
Performance
6
COP
1
4.37 4.47 4.47 4.26
COP
2
3.81 3.99 4.05 3.81
Heating capacity
2
kW 6.20 7.93 10.2 11.2
Power input
2
kW 1.6 2.0 2.5 2.9
Nominal flow
3
Heating circuit l/s 0.3 0.4 0.5 0.5
Lowest outdoor temperature
allowed for compressor start
°C –16 –16 –16 –16
Max temperature
4
Heating circuit °C 60 60 60 60
Pressure switches Low pressure MPa 0.03 0.03 0.03 0.03
Operating MPa 2.85 2.85 2.85 2.85
High pressure MPa 3.10 3.10 3.10 3.10
Water volume Condensor l 1.3 2.2 2.7 2.7
Number of units 2 2 2 2
Outdoor unit Dimensions LxWxH mm 661x1167x1290 661x1167x1290 661x1167x1290 661x1167x1290
Weight kg 108 113 123 140
Sound power level
5
dB(A) 67.7 67.8 68.1 70.4
Fan speed rpm 890 890 890 940
Air flow m
3
/h 3667 3667 3667 4045
Control unit Dimensions LxWxH mm 210x380x600 210x380x600 210x380x600 210x380x600
Weight kg 18 18 18 18
The measurements are performed on a limited number of heat pumps
which can cause variations in the results. Tolerances in the measuring
methods can also cause variations.
1) At A7W35 10K warm side.
2) At A7W35 according to EN 14511.
3) Nominal ow: heating circuit 10K.
4) At minimum outdoor temperature 0°C.
5) According to ISO 3741.
6) The values apply to a new heat pump with clean heat exchangers.
VDBMX102
1
2
1167
661
405
495 76
325
243
1250
773
1
2
1167
661
405
495 76
325
243
1250
773