Brochure

26 AB218186428184en-US1501
GENERAL INFORMATIONPRODUCT INFORMATIONINTEGRATION INTO SYSTEMORDERING INFORMATION SYSTEM DESIGN
Design compressor mounting
General requirements
Single requirements
Compressors used in single applications must be
mounted with flexible grommets.
Compressors used in parallel application must be
mounted with rigid mounting spacers onto rails
and the manifold assembly must be mounted
with flexible grommets onto frame.
During operation, the maximum inclination from
the vertical plane must not exceed 3 degrees.
H-series compressors come delivered with
flexible grommets, accessory Mounting kit
120Z5064.
The grommets must be compressed until contact
between the flat washer and the steel mounting
sleeve is established. The required bolt size for
the H-series compressors is M8*1.57inch. This
bolt must be tightened to a torque of 8ft.lbs.
0.067
1.614
Ø 1.614
1.161
5/16” - 18 UNC
self tapping
Recommended torque for mounting bolts:
8 ft.lbs (±1ft.lbs)
Ø 0.433
Tandem
requirements
For parallel mounting, the compressor must be
mounted with rigid mounting spacers (included
in the tandem kit 120Z0636) on the rails.
Rubber grommets and sleeves (delivered with
the compressor) must be installed below the rails.
Parallel mounting feet
Included in tandem
Supplied with the compressor
Not supplied