Brochure
25AB218186428184en-US1501
GENERAL INFORMATIONPRODUCT INFORMATIONINTEGRATION INTO SYSTEMORDERING INFORMATION SYSTEM DESIGN
Tandem requirements Danfoss scroll compressor H series tandem use
static oil balancing principle to equalize oil level
between the compressors by gravity. This is
ensured by a precise suction and oil equalization
piping designs.
The discharge line as no impact on oil balancing
and is shown with tees, to indicate that both left
and right side discharge header are possible
Danfoss scroll H series compressors in C8 version
can be mounted in tandem assemblies.
By default, H series tandems are not factory-built,
just provide tandem version compressors
(feature 8).
Such manifolding applications require special
design considerations that go beyond the scope
of this document. Please contact Danfoss for
further information.
For each tandem configuration, specific outline
drawings are available as indicated in following
tables.
Suction and oil & gas equalization piping
drawing must be respected (diameters, minimum
straight lengths)
R
Tandem model Comp.1 Comp.2
Connection Sizes
Oil equalization
(in)
Gas equalization
(in)
Kit tandem
Code No
Outline drawing
number
Suction
(in)
Discharge
(in)
TLJ082 HRH041 HRH041 1-1/8" 3/4" 1/2" 7/8" 120Z0636 8556080
TLJ098 HRH049 HRH049 1-1/8" 3/4" 1/2" 7/8" 120Z0636 8556080
TLJ122 HLH061 HLH061 1-1/8" 3/4" 1/2" 7/8" 120Z0636 8556080
TLJ136 HLH068 HLH068 1-1/8" 3/4" 1/2" 7/8" 120Z0636 8556080
TLJ144 HLJ072 HLJ072 1-1/8" 3/4" 1/2" 7/8" 120Z0636 8556080
TLJ166 HLJ083 HLJ083 1-1/8" 3/4" 1/2" 7/8" 120Z0636 8556080
TCJ181 HCJ091 HCJ091 1-5/8" 1-1/8" 1/2" 1-1/8" 120Z0636 8556153
TCJ211 HCJ106 HCJ106 1-5/8" 1-1/8" 1/2" 1-1/8" 120Z0636 8556153
TCJ241 HCJ121 HCJ121 1-5/8" 1-1/8" 1/2" 1-1/8" 120Z0636 8556153