02E5 electronic miniprogrammer for controlling hot water and heating Installation & User Instructions including Factory Replacement Units (FRU)
Index Installation Product specification 3 Installation 4-6 Wiring 6-9 Replacement 10-11 INDEX User 2 Your programmer 12 Setting the clock 13 Factory preset programmes 14 Setting the programme - 24 hour 15 Setting the programme - 5/2 day 16 Running the programme 17 Temporary user overrides 18 Battery backup 19 Contact details 20
Installation Instructions Please Note: This product should only be installed by a qualified electrician or competent heating installer, and should be in accordance with the current edition of the IEEE wiring regulations. Product specification Power supply 230 ± 15% Vac, 50 Hz Switching action 1 x SPST, Type 1B Switch rating 264 Vac, 50/60Hz, 3(1)A Timing Accuracy ±1 min./month Power Reserve Minimum 14 days Enclosure Rating IP30 Max.
Installation NB. For FRU units - go straight to point 6 below. 1. Loosen the fixing screw in the base of the unit to release the Wiring Cover. 2. Holding the unit face downwards, press firmly in the centre of the wallplate and slide it apart and lift it from the module. 3. Fix the wallplate and terminal block to the wall, or plaster box, as required.
. Electrical connections are simplified by using a Wiring Centre. However, if this is not used, the wallplate terminal identification is as shown. Water Heating Mains Supply (via 3 amp fuse) ON ON COM 1 2 3 N L 5 6 If the system being controlled is 230Vac then terminals 3 and L must be linked with insulated cable capable of carrying full load current. Whilst the unit does not require an earth connection, a terminal is provided on the wallplate for earth continuity purposes. 7.
10. Then press the SELECT button until the bar lines up with the word OFF and check the system does not operate. 11. Set the rocker switch to WATER ONLY. Press the SELECT button until the bar in the display lines up with the word ON and check that the water circuit only operates. 12. When the circuit check has been completed, replace the wiring cover and tighten the fixing screw. Cut any cable aperture in the wiring cover which may be necessary to accommodate surface mounted cables. 13.
Typical Gravity DHW with Pumped Heating 2 1 5 3 6 102E5 TERMINALS LINK L COM N ROOM 'STAT L N N BOILER TERMINALS L N PUMP TERMINALS Typical domestic gas or oil-fired central heating system with gravity hot water and pumped heating. (If a room thermostat is not used, wire pump live directly to terminal 2 of the 102E5).
Typical Heating and Hot Water control system using 3-port mid-position valve 2 1 5 3 6 102E5 TERMINALS LINK L ROOM 'STAT COM CALL N WHITE BLUE OR BROWN N CYL. 'STAT COM SAT CALL GREY RED OR ORANGE Wiring MID-POSITION VALVE 8 L N MAINS SUPPLY FUSED 3 AMP BOILER & PUMP TERMINALS The above control system is available as the Danfoss Randall 102E5 HEATSHARE pack, which also includes the TW room thermostat, AT cylinder thermostat, HS3 midposition valve and a WB12 wiring box.
Typical Heating and Hot Water control system using 2-port zone valves 2 1 5 3 6 102E5 TERMINALS LINK COM L COM ROOM 'STAT SAT CALL CYL. 'STAT N N MAINS SUPPLY FUSED 3 AMP CALL HEATING VALVE N N L N BOILER & PUMP TERMINALS The above control system is available as the Danfoss Randall 102E5 HEATPLAN pack, which also includes the TW room thermostat, AT cylinder thermostat, two 22mm HPP zone valves and a WB12 wiring box. Wiring D.H.
2 2 2 1,3 HORSTMANN DIAMOND 424 POTTERTON 423 SANGAMO S409 F1 & F4 SANGAMO (Early model) S410 Form 4 Boiler (8) HORSTMANN CORAL 423 & 424 2 4 RANDALL MKII R6 HORSTMANN DIAMOND 423 4 RANDALL 3020P, 3060 4 5 4 4 4 Air ‘Stat (8) 5 2 2 2 1 1 Heating ON Water ON RANDALL 102, 102E, 102E7 DANFOSS RANDALL 102E5 - - - - - - - - 3 3 COM Replacement N,2 N,1,3 N N N 2,3 3 1,7 5 5 (N) L L L,1,3 L,1,3 L,1,3 1 1,2 6 6 6 (L) MAINS SUPPLY (via 3 amp fuse)
3 5 3 5 3 3 V 2 2 SMITHS IND. CENTROLLER 100 SMITHS IND. CENTROLLER 60 SMITHS IND. CENTROLLER 10 SMITHS IND.
User Instructions Your programmer Your 102E5 mini-programmer allows you to switch your heating and hot water on and off at times that suit you. Overview The 102E5 can provide 3 ON periods and 3 OFF periods each day and can offer either 24 hour control (same programme for each day of the week) or 5/2 day control (one set of programmes for weekdays and a different set for weekends).
Before you start Open the flap on the front of the unit. Press all four buttons (SELECT / ADVANCE / + / -) at the same time - + PROGRAMME Setting the clock Press PROGRAMME once Use + and – buttons to set the correct time (press and hold to change in 10 min increments). When time is correct press PROGRAMME again. + - PROGRAMME + - PROGRAMME In 24 hour mode this will take you straight to programming mode, where you can select your own ON and OFF times.
Factory Presets Factory preset programmes The unit is supplied with the following preset programme which will be active after the unit has been reset. Mon-Fri or All days in 24hr mode Sat-Sun* (5/2day mode only*) 1st ON 6.30am 7.30am 1st OFF 8.30am 10.00am 2nd ON 12.00pm 12.00pm 2nd OFF 12.00pm 12.00pm 3rd ON 5.00pm 5.00pm 3rd OFF 10.30pm 10.30pm NB. 2nd ON and 2nd OFF are set to the same time.
Programming event times in 24 hour mode You can programme your heating and hot water to come on and go off up to 3 times each day, to suit your requirements. 1 Use the + and - buttons to set the time you want your system to first come on in the morning Press PROGRAMME again to move to the next step (Event 2) Use the + and - buttons to set the time you want your system to first go off. Continue using the PROGRAMME and +/- buttons in this way to set the ON/OFF times for events 3-6 (2nd ON/OFF & 3rd ON/OFF).
Programming event times in 5/2 day mode You can programme your heating and hot water to come on and go of up to 3 times each day, to suit your requirements, with one set of programmes for weekdays and a different set of programmes for the weekend. Programming the unit - 5/2 day mode Weekdays (MOTUWETHFR) Press PROGRAMME until 1 (Event 1) shows along the top of the display and MOTUWETHFR shows along the bottom.
Running your programme The 102E5 will either control your hot water and heating together, or just your hot water (i.e. during the summer, when heating is no longer required).
Temporary User Overrides Sometimes you may need to change the way you use your heating temporarily, i.e due to unusually cold weather. The 102E5 has two convenient overrides which can be selected without affecting the set programme. Override buttons Override buttons +1HOUR Press +1HOUR once if you need an extra hour of operation (a red light will come on). If the system is off it will come on for an hour. If it is already on it will add an extra hour so the system stays on for an extra hour.
Battery backup In the event of a power cut, the built-in lithium battery will keep your time and programme settings for up to 15 days. After 15 days without mains power the unit will switch off and two dots will show in the display. However all your programmed on/off times will be remembered. Battery backup When the mains power is restored, the unit will need to be reactivated by pressing the PROGRAMME button, and the time and day will need to be set (see page 13).
Still having problems? Call your local heating engineer: Name: Tel: Visit our website: www.danfoss-randall.co.uk Email our technical department: drl_technical@danfoss.com Call our technical department 0845 121 7505 (8.45-5.15 Mon-Thurs, 8.45-4.45 Fri) For a large print version of these instructions please contact the Marketing Services Department on 0845 121 7400.