Product Overview
Class A GFCI Laminate Wood Floors
The thermostat features a built-in Class A GFCI (Ground Fault The 008L5132 model is designed specifically for laminate &
Circuit Interrupter). Should a ground fault occur, the GFCI engineered wood floors. It uses an air sensor to control the
disconnects both lines to the heating element. The thermostat floor heating with a floor sensor that acts as a high limit to
and GFCI are dual voltage models suitable for 120/240 V, 50/60 prevent the laminate or engineered wood floor from over
Hz power supplies. heating. Please refer to Danfoss Reflect for optimal laminate
and engineered wood heating performance.
Fully Programmable
The thermostats are supplied with factory-set 4-event Backup function
program for automatic comfort and set-back temperatures. In the event of a power failure, an internal circuit will maintain
The factory-set periods and/or temperatures can be changed the programming and time. However, the time must be reset if
according to requirements. the power failure exceeds two hours.
Furthermore, the following programs can be selected:
• 4 events for 5 days and 2 events for days 6+7
TECHNICAL DATA
• 4 events for 6 days and 2 events for day 7
Supply................................................. 120/240 Vac 50/60 Hz
• 4 events per day
Load.........................................15A maximum (resistive load)
The programmable thermostat features an adaptive function,
Power.................... 1.800 W at 120 Vac / 3.600 W at 240 Vac
allowing it to calculate when the heating must be switched on
GFCI..................................................Class A (5 mA trip level)
to ensure that the comfort temperature is reached at the
Temperature range..................... +41 to +104°F.(+5 to +40°C)
required time.
Floor limit range.......................... +41 to +104°F.(+5 to +40°C)
Amb. Temp. range........................+32 to +104°F (0 to +40°C)
Comfort mode Clock function.............................................. 4-event program
The room temperature can be temporarily changed for a On/Off differential.............................................. 0.7°F (0.4°C)
single event. The comfort mode temperature is reset after a Regulation principle..................................................PWM / PI
selected number of hours. The thermostat will then return to Housing............................................................ Nema 2 (IP21)
the scheduled event program. Floor sensor type.............................. NTC (12 KΩ) 10 ft (3 m.)
Dimensions(H/W/D) ............. 4.8/3.0/1.0 inch (123/75/25mm)
Manual mode
The scheduled event program can be cancelled, e.g. during
c-UL-us according to the following standards:
holidays, and the temperature set for frost protection
Thermostat: UL 873
purposes instead, e.g. to 41°F (5°C). The new set-point will
CSA C22.2 No. 24
remain active until manual mode is cancelled. UL E-file: E157297
GFCI: UL 943
CSA C22.2, No. 144. 1-06
Monitoring of energy consumption
Total switch-on time in percent can be displayed for the last 2
days, 30 days or 365 days. Overall energy consumption can
Ordering Information
thus be monitored.
088L5130 Floor sensing
088L5132 Air sensing with floor temperature
limiter
Danfoss Inc.
Toronto
Fax: 905-285-2055
www.LX.Danfoss.com
Toll Free: 1 866 676-8062
Phone: 905 285-2050
Copyright 2009 Danfoss Inc.
NA.EFHSS.LXTSTAT