User Guide
8
Operation Instructions
Changing parameters and performance of systems
Several parameters for each system can be changed during and after the installation.
For a complete understanding of how these parameters aff ect the performance of the
roof and ground system, please refer to Appendix B: “How it works”.
Only change the GX™ 850 parameters if you are aware of the eff ects of
your actions.
Reference: Appendix A: Installer menu
Roof system
Melting temperature
Changing the melting temperature will aff ect when the system is activated in case of
moisture and low temperatures.
The factory setting is 35 °F (1.5°C).
This means that the heating system will be activated if the temperature falls below 29
° F (1.5°C) and moisture is detected.
Moisture level
The “moisture level” decides when the system detects moisture.
The factory setting is 50 (on a scale from 5 to 95).
The lower the setting, the more sensitive the system is to moisture.
Post-heat
Once the sensor has detected that the roof/gutter is dry and free of ice and snow the
system will keep heating for another hour (default). If you wish to increase/decrease
this time see capital A: Installer menu.
The factory setting is 1 hour (on a scale from 0 to 9 hours)
Priority
When using the GX™ 850 as a dual or combi system, it is possible to prioritize the sys-
tems. When the priority of 2 systems is equal, both systems can heat at the same time.
If the priority of the 2 systems diff ers, and both systems want to heat, only the system
with the highest priority is allowed to heat.
The factory setting is 1 (highest priority) for all systems.
Clogged drain
It is possible to enable and disable the “Clogged drain warning”.
The factory setting is “Warning On”.
System and sensor name
It is possible to change the names of the system and connected sensors (see capital A:
Installer menu.
Appendix
25
Installer menu
Setparameter
Moist.lev.=50
Setparameter
Stdb.T=-3.0≥C
Setparameter
Melt.T=4. 0≥C
Setparameter
Postheat=1h
Cloggeddrain
WarningOn
View
statistics
Leavethismenu:
PressÛ
EnterMoist.Lev
0_
EnterStdb.temp
-00.0≥C
EnterMelt.temp
1.0≥C
Enterpostheat
0hours
Select:
WarningOn
Renamesystem:
Roof
Entername:
Roof
Entername:
Roof
Entername:
Soof
Entername:
Rpof
Setparameter
Priority=1
EnterPriority
1(High)
Renamesensors
insystem
Renamesensor:
Sensor1
Entername:
Sensor1
Renamesensor:
Sensor2
Leavethismenu:
PressÛ
View statistics
Installer menu
Entername:
Sensor2
Restorefactory
parameters
Changesystem
Change system
Selecttemp.
indicationÙC
Selecttemp.
indicationÙC
Setparameter
Language
Selectlanguage
English
Appendix A