User Guide
26
Appendix
Change system
Appendix A
Change system
Checkingsystem
<------>
Noground
sensorsfound!
Only if any pas s ive (disabled)
sensors are working again!
1sensor(s)
reactivated!
Replacesensor:
Sensor103FB2F
Addsensor:
ID:03ABC1
Addsensor:
ID:03DEF1
Canceladd
sensor?
Replacesensor:
Sensor203FC24
Cancelreplace
sensor?
Sensoradded!
Sensorreplaced!
Addsensor:
ID:03ABC1
Addsensor:
ID:03DEF1
Cancelreplace
sensor?
If no new sensors are found
(Example showing ground
system).
If new sensor(s) found, but no
passive sensor(s) found.
If new s ens or(s) found and
passive sensor(s) found.
Operation Instructions
7
Possible alarms during operation
Clogged drain
Description: When clogged drain warning has been enabled, the system constantly has
been detecting moisture for 14 days.
If the GX™ 850 controls more than 1 system, and prioritizing has
been enabled, the time before clogged drain warning for the
down-prioritized system, can be much longer. The time is only
updated when the system actually is allowed to heat the area
(e.g. the higher priority system is not heating)
Solution: - Check gutter and down pipes for any obstacles preventing the melting
water to fl ow away.
- Check if sensors are covered with dirt.
Missing sensor
Description: When the connection to a sensor is lost, the GX™ 850 alerts the user. At the
same time the GX™ 850 automatically switches the system to “Constant
Off ” mode, and user interaction with the GX™ 850 is needed.
Solution: - Acknowledge error and go to “Installer Site” in the menu system and
select “Change System”.
- Contact your local installer to get a replacement.
New sensor added
Description: When a new sensor is added, the GX™ 850 alerts the user and at the same
time automatically switches to “Constant Off ” mode. User interaction is
needed in order to correct the error.
Solution: Acknowledge error and go to “Installer Site” in the menu system and select
“Change System”.
Sensor malfunction
Description: When something is wrong with the readings from connected sensors to
the GX™ 850, an alarm is raised.
Not all error prone sensors can be discovered using this feature!
Solution: - Acknowledge error and go to “Installer Site” in the menu system and
select “Change System”.