User Guide

16
Setup Instructions
Setup of dual zone system
The installation of a GX™ 850 with 2 roof systems or 2 ground systems has been se-
lected.
It is mandatory that no sensors or only sensors for System A are connected to the the
GX™ 850 before power up. Sensors for System B must be connected to the GX™ 850
during the installation steps. Connection of the sensors during installation can either
be done using a switch on the DIN-rail or just connect sensor bus of System B to the
already connected sensor bus of System A.
The rst installed system (System A) is using the output System A.
The second installed system (System B) is using the output System B.
If sensors for System A are not connected - do it now!
Press
or wait…
System is being scanned to fi nd type of connected
sensors…
Select system type
Wait until correct number of sensors for System A is
found.
Press
when all sensors for System A are found…
System A is installed…
Connect sensors for System B.
Press
or wait…
System is being scanned to fi nd type of connected
sensors…
Select system type
Connect sensors:
System A
System A
Scanning...
System type:
Ground
1 Ground sensor
found. Accept?
System A
Installed!
Connect sensors:
System B
SystemB
Scanning...
Systemtype:
Ground
Setup Instructions
17
Press to end
Configuration.
Config system:
SystemB
Config system:
System A
Checking system
<------>
SystemB
Installed!
1 Ground sensor
found. Accept?
Wait until correct number of sensors for System B is
found.
Press
when all sensors for System B are found…
System B is installed…
System is being checked…
Press
to select system to confi gure.
Press
to confi gure selected system.
(Naming sensors, changing factory settings and
setting priorities)
Please refer to “Changing parameters and performance
of systems” in “User Manual” for description of the
confi gurable parameters.
Press
to end confi guration.