User Guide
14
Setup Instructions
Connect sensors:
System A
System A
Scanning...
System type:
Roof
1 Roof sensor
found. Accept?
Setup of combination system
The installation of a GX™ 850 with 1 roof system and 1 ground system has been se-
lected.
It is optional if the sensors are connected to the GX™ 850 before power on or during
the installation.
The fi rst installed system (System A) is using the output System A.
The second installed system (System B) is using the output System B.
It is freely selectable if System A should be the roof or ground system. However it is
preferable that System A is the roof system, since System A is shown on the upper line
of the display. Please refer to the description of the Display and Combined view in the
user manual.
If sensors for System A are not connected - do it now!
Press
or wait…
System is being scanned to fi nd type of connected
sensors…
Select system type: Roof
(if roof system is preferred as System A)
Wait until correct number of sensors for System A
is found.
Press
when all sensors are found…
System A is installed…
If sensors for System B are not connected - do it now!
Press
or wait…
System is being scanned to fi nd type of connected
sensors…
Select system type: Ground
(if ground system is preferred as System B)
Connect sensors:
System B
System B
Scanning...
System type:
Ground
System A!
Installed
Setup Instructions
19
Replace sensor:
Sensor1 03FB2F
Replace sensor:
Sensor2 03FC24
Cancel replace
sensor?
Add sensor:
ID: 03ABC1
Add sensor:
ID: 03DEF1
Cancel replace
sensor?
Sensor replaced!
Replace a malfunctioning sensor:
From the installer menu select Change system.
The system is searching for connected sensors.
The user selects the passive sensor, which should be
replaced with a new one.
Press
to loop through the found passive sensors
or to cancel replace sensor.
Press
when the correct passive sensor or “Cancel
replace sensor?” is selected.
If the user selected a passive sensor to replace, the user
should now select the new sensor.
Press
to loop through the found new sensors or
to cancel replace sensor.
Press
when the correct new sensor to add is found
or “Cancel replace sensor?” is selected.
If the user selected a new sensor to add, the replacing
of the sensors is performed.
Checking system
<------>