User Guide

10
Operation Instructions
Setup Instructions
System overview
The GX™ 850 can handle up to 2 independent areas, in any of the following
combinations:
Single roof system
(1 system, 1-4 roof sensors)
Single ground system
(1 system, 1-4 roof sensors)
1 ground system and 1 roof system (combi system)
(2 systems, 2-4 sensors total, minimum 1 sensor per system)
2 roof systems (dual system)
(2 systems, 2-4 sensors total, minimum 1 sensor per system)
2 ground systems (dual system)
(2 systems, 2-4 sensors total, minimum 1 sensor per system)
Zone A is used for single system. When two zones are utilized, Zone A is always the
priority.
A typical ice and snow melting system consists of:
GX™ 850
Only 1 GX™ 850 is allowed on the Devibus™
Power supply
More power supplies can be connected in parallel (if needed)
Be aware of maximum number of sensors on each power supply
(Refer to Technical Specifi cation for power demand of sensors)
Ground and/or roof sensor(s)
Be aware of maximum number and cable length of sensors on each power supply
(Refer to sensor manual for a more detailed description)
Setup Instructions Appendix
23
Appendix
A: Menu system
Main menu
System
B
System
A
A:Roof˜
ÚStandby
B:Ground¯ˆı
ÚMelting
Selectsystem A:
Roof
Selectsystem B:
Ground
Viewalarm
menu
5s
A:Roof˜
B:Ground¯ˆı
5s
Viewandset
operatingmode
Viewsensor
measurements
Viewandset
operatingmode
Viewsensor
measurements
Only visible when System B is installed!
System menu
Viewandset
operatingmode
Viewsensor
measurements
Viewsystem
parameters
Currentmode:
Automatic
Selectmode:
Automatic
Selectmode:
ConstantOFF
Selectmode:
ConstantON
Leavethismenu:
PressÛ
Installer
site
Proceed?
ÛÛÛYesΩNo
Installer menu
Leavethismenu:
PressÛ
View sensor measurements
View system parameters
System menu (A / B)
Return to main
Appendix A