Product Overview
Data Sheet DS-2C Built-in Sensor/Controller
for Snow Melting Applications
© Copyright 2014 Danfoss NA.EFH.DS2BD.09/14 TEL: 866-676-8062, FAX: 905-285-2055 1
General
Information
Technical Data
Supply: 100-277V Universal input power supply
Max. Heating Load: 30A @ 240 VAC
Operating Temperature: -40°F to 185°F (-40°C to 85°C)
Enclosure Type: NEMA 3R
Mounting: Pole or Wall Mounted, outdoors
Dimensions (HxWxD): 4.75” x 7.0” x 2.75” (121mm x 178mm x 70mm)
Trigger Temperature: 34°F to 44°F (1.1°C to 6.6°C), Field Selectable
Delay Timer: 30-90 minutes, Field Selectable
it can be used as a stand alone controller or as a
sensor for larger systems. It regulates cable
operation in driveways, sidewalks, and ramps.
• Housed in a weatherproof enclosure
• Senses both moisture and temperatures
• Adjustable temperature trigger point
• Expanded 30-90 min. & 2-6 hr. delay o drying
time
• Manual override capable
• Selectable low temperature cuto with unique
Recover module
• Super bright front panel power/activation LED
indicator
• Remote control and monitor capabilities
• Easy to install
• Two year warranty
Internal Diagram
The DS-2C is designed for economical and
eective control of heating cables in
residential and commercial snow and ice
melting applications. With versatility in mind,