Data Sheet ECtemp™ Smart – Intelligent Electronic Timer Thermostat
2
VDIOP102 © Danfoss 07/2016
Danfoss A/S
Electric Heating Systems • Ulvehavevej 61 • DK-7100 Vejle • Denmark • Phone: +45 7488 8500 • Fax: +45 7488 8501
EH@danfoss.com • http://heating.danfoss.com/new-solutions/ectemp-smart
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Technical specifications
Operation voltage 220 V- 240V~ 50/60 Hz
Standby power consumption max. 0,40 W
Relay:
Resistive load
Inductive load
16A / 3680W @ 230V
1A (Cos Φ = 0,3)
Sensing unit NTC 15 kΩ @ 25°C, 3 m (default)
NTC 6,8 kΩ @ 25°C
NTC 10 kΩ @ 25°C
NTC 12 kΩ @ 25°C
NTC 33 kΩ @ 25°C
NTC 47 kΩ @ 25°C
Regulation PWM - Pulse Width Modulation
Ambient temperature 0°C to 30°C
Frost protection 5°C to 9°C (default 5°C )
Floor temperature limit Max. 20°C to 35°C (45°C)
Min. 10°C to 35°C (45°C)
Temperature range 5°C to 35°C (room)
5°C to 45°C (floor)
Storage temperature -20°C to 65°C
Cable specification max. 1 x 4 mm²
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1 C
Software class A
IP class 21
Protection class
Class II -
Dimensions (H/W/D) 85 mm x 85 mm x 20-24 mm
(in-wall depth: 22 mm)
Weight 127 g