Submittal Sheet
Data sheet Thermostatic expansion valves, type TUA/TUAE and TCAE
8 DKRCC.PD.AG0.A4.22 / 520H8945
Capacities (TR)
R407C
Range N: -40 °F – 50 °F. ∆t
sub
= 10 °F, OSH = 7 °F
Type
Orice
no.
Cond. temp.
[°F]
Evaporating temperature [°F]
-40 -30 -20 -10 0 10 20 30 40 50
Capacity in TR
TU
0
75
0.071 0.082 0.094 0.107 0.121 0.136 0.150 0.162 0.171 0.174
1 0.102 0.118 0.135 0.155 0.175 0.196 0.216 0.233 0.246 0.249
2 0.114 0.131 0.152 0.174 0.199 0.225 0.251 0.275 0.295 0.305
3 0.155 0.179 0.205 0.235 0.267 0.300 0.332 0.360 0.381 0.389
4 0.243 0.282 0.326 0.377 0.433 0.493 0.556 0.617 0.670 0.705
5 0.328 0.379 0.439 0.507 0.581 0.662 0.744 0.824 0.891 0.934
6 0.505 0.585 0.677 0.782 0.900 1.030 1.160 1.290 1.400 1.480
7 0.669 0.774 0.896 1.040 1.190 1.360 1.530 1.700 1.850 1.950
8 0.991 1.150 1.330 1.540 1.770 2.010 2.260 2.500 2.690 2.800
9 1.310 1.520 1.760 2.040 2.360 2.710 3.080 3.440 3.770 4.010
TC
1 2.480 2.800 3.130 3.470 3.800 4.110 4.370 4.550 4.630 4.540
2 2.680 3.040 3.430 3.830 4.230 4.620 4.960 5.210 5.330 5.260
3 3.110 3.550 4.030 4.540 5.070 5.590 6.080 6.470 6.690 6.670
Determine if external equalization is required.
Note! External equalization is always required if
a distributor is used or if there is an appreciable
dierence in pressure (>8 psi ) from the valve
outlet to the bulb location.
Finally, determine connection sizes, then nd the
valve´s code number from the tables on
page 4 - 6.
Select a thermostatic charge.
Danfoss oers a universal wide range
thermostatic charge, Range N, suited for most
applications in the normal temperature range.
Ranges NM and B are available for special low
temperature applications.
Step 5
Step 4
Step 3
Use the calculated valve capacity (2.56 TR) to
select the corresponding orice size from the
capacity table for R407C as indicated below.
Note that the expansion valve capacity must
be equal to or slightly more than the corrected
evaporator capacity.
In this sizing example, orice 9 will be suitable.