Brochure

2
VDKIS322 © Danfoss 07/2016
Data Sheet
ESBE VTA Series Lead Free
Thermostatic Mixing Valves
temperatures at the source while maintaining
appropriate water temperatures out to the
xtures. With a higher temperature at the source,
the installation benets of the VTA series include:
Additional volume of domestic hot water
through the thermostatic control of
temperature to the xtures
Preventative measures to reduce growth
of Legionella by maintaining a high
temperature within the source and
safeguarding against scalding down stream
In the event there is a cold-water supply failure,
the hot water supply closes automatically.
The angle ow pattern of the ESBE VTA series
thermostatic mixing valves combine high quality
performance with remarkable ease of installation
and servicing.
Solder c/w 2 check valves (Union connection)
CPVC (Union connection)
Maximum working pressure:
150 psi (10 bar) / CPVC: 80 psi (5.5 bar).
Maximum dierential pressure
between hot and cold ports: 44 psi (3 bar).
Maximum system dierential pressure
between outlet and inlet ports: 72 psi (5 bar).
Maximum hot water inlet temperature:
194°F (90°C).
Minimum required ow for proper
temperature regulation:
All valves except 1” NPT, 0.9 GPM
1“ NPT valve size, 2.0 GPM
Up to a 50% glycol mixture for closed loop
hydronic system
Applications:
Specications:
The compact ESBE VTA series are Lead Free (LF)
thermostatic mixing valves designed for Point
of Source in domestic hot water distribution
systems and/or regulation of supply in hydronic
heating systems. The series of LF valves meet
the NSF/ANSI 372 standards for ‘lead free’
requirements, which took eect in January 2014.
The VTA series of valve replaces the Series 20 and
30MR styles of valves. The VTA series is available
in four temperature ranges:
85-120°F (30 – 4C) (Domestic/ Hydronic)
95-140°F (35 – 6C) (Domestic/ Hydronic)
70 -110°F (20 – 4C) (Hydronic)
85-160°F (30 – 70°C) (Hydronic)
As a Point of Source for domestic hot water
application, the thermostatic control within
the VTA valve accommodates increased water
Conforms to ASSE-1017*
Anti-scald function*.
Designed for mixing purposes.
Long life and easy maintenance.
Quiet operation.
Compact design and lightweight.
Snap-on cover for dirt protection and to
prevent unauthorized adjustment or
tampering.
Cover label for recording setting
information including recorded outlet
temperature and date installed.
*Only ranges 85°-120°F and 95°-140°F meet ASSE-1017
standard.
Available connections:
Threaded body (FNPT)
Solder (Union connection)