Product Overview

Data sheet | Pressure switch, KP
DKRCC.PD.CD0.1A.02 | 520H11562 | 5
Pressure switches PED 2014/68/EU approved; EN 12263
For R22, R134a, R404A, R407A, R407C, R407F, R410A*), R422B, R422D, R438A, R448A, R449A, R450A, R452A, R507A, R513A
*) for KP6W, KP6B
For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are listed as part
of technical data.
Pressure
Type
1
)
Low pressure (LP) High pressure (HP) Reset
Contact
system
Code no.
Connection
Regulating
range
Dierential
∆p
Regulating
range
Dierential
∆p
Low
pressure
High
pressure
1
/
4
in.
6 mm
are
6 mm
ODF
solder
[bar] [bar] [bar] [bar] LP HP
Low KP 1 -0.2 – 7.5 0.7 – 4.0 Auto SPDT 06 0 -11016 6
2
)
3
) 06 0 -111066
3
)
Low KP 1 -0.9 – 7 0.7 Man. (Min.) SPDT 0 60 -110366
2
) 06 0 -1109 66
Low KP 2 -0.2 – 5 0.5 – 1.5 Auto SPDT 060-112066
2
)
3
) 06 0 -112366
3
)
High KP 6W 8 – 42 4 – 10 Auto SPDT 060-519066
3
)
High KP 6B 8 – 42 4 Man. (Max.) SPDT 060-519166
High KP 7W 8 – 32 4 – 10 Auto SPDT 060-119066
3
) 060 -120366
3
)
High KP 7B 8 – 32 4 Man. (Max.) SPDT 060 -119166
High KP 7S 8 – 32 4 Man. (Max.) SPDT 060 -11926 6
3
)
Dual KP 7BS 8 – 32 4
Man. (Max.)
Man. (Max.)
SPST 060-120066
Dual KP 17W -0.2 – 7.5 0.7 – 4 8 – 32 4 Auto Auto
SPDT + LP and
HP signal
060-127566
3
) 060-127666
3
)
Dual KP 17W -0.2 – 7.5 0.7 – 4 8 – 32 4 Auto Auto
SPDT+ LP
signal
060-126766
3
)
Dual KP 17B -0.2 – 7.5 0.7 – 4 8 – 32 4 Auto
Man. (Max.)
SPDT 060 -126866 060-127466
Dual KP 17WB -0.2 – 7.5 0.7 – 4 8 – 32 4 Auto Conv.
5
)
SPDT + LP and
HP signal
060-539766
3
)
4
)
For R717, R22, R134a, R404A, R407A, R407C, R407F, R422B, R422D, R438A, R448A, R449A, R450A, R452A, R507A, R513A
For complete list of approved refrigerants, visit www.products.danfoss.com and search for individual code numbers, where refrigerants are
listed as part of technical data.
Pressure Type
Low pressure (LP) High pressure (HP) Reset
Contact
system
Code no.
Connection
Regulating
range
[bar]
Dierential
∆p
[bar]
Regulating
range
[bar]
Dierential
∆p
[bar]
Low
pressure
LP
High
pressure
HP
M10 × 0.75
1 m cap.
tube with
M10 × 0.75
Low KP 1A -0.2 – 7.5 0.7 – 4.0 Auto SPDT 06 0 -116266
2
) 060-116066
3
)
Low KP 1A 0.9 – 7 Fixed 0.7 Man. (Min.) SPDT 060-116166
Dual KP 7ABS 8 – 32 Fixed 4
Man. (Max.)
Man. (Max .)
SPST 060-120566
1
) W = PSH (pressure switch), B = PZH (pressure switch with ext. reset),
S = PZHH (pressure switch with int. reset)
2
) Available in Asia market with code 060-xxxx91
3
) Enclosure IP44
4
) Factory setting: LP side: Range 1 bar Pe, Di. 1 bar;
HP side: Range 18 bar Pe, Di. 4 bar xed
5
) Conv.: optional automatic or manual reset
Pressure switch setting with convertible reset
Low pressure Manual reset
1
) Automatic reset Automatic reset Manual reset
High pressure Manual reset
1
)
Manual reset Automatic reset Automatic reset
1)
Factory setting
© Danfoss | DCS (rm) | 2019.03