Product Overview
Data sheet | Pressure switch, KP
DKRCC.PD.CD0.1A.02 | 520H11562 | 3
Technical data
(continued)
Cable connection
The cable entry can be used for 6 – 14 mm
dia. cables. A Pg 13.5 screwed cable
entry can also be used for 6 – 14 mm cable.
With 8 – 16 mm cable a standard Pg 16 screwed
cable entry can be used.
Enclosure
IP30 to EN 60529 / IEC 60529
Enclosure IP30 is obtained when the units
without top cover are mounted on a at surface
or bracket. The bracket must be xed to the unit
so that all unused holes are covered.
IP44 to EN 60529 / IEC 60529
Enclosure IP44 is obtained when the units
with top cover are mounted on a at surface
or bracket. The bracket must be xed to the unit
so that all unused holes are covered.
KP pressure switches with auto reset are supplied
with top cover. For KP pressure switches with
manual reset, the top cover must be separately
ordered (code no. 060-109766 for single
pressure switches and code no. 060-109866 for
dual pressure switches).
IP55 to EN 60529 / IEC 60529
IP55 is obtained when the KP pressure switches
are mounted in an IP55 enclosure,
(code no. 060-033066 for single pressure
switches and code no. 060-035066
for dual pressure switches).
IP55 enclosure has to be ordered separately.
Materials in contact
with the medium
Type Material
KP 1, KP 2, KP 5, KP 6,
KP 7, KP 15 and KP 17
Tinbronze, no. CW452K, EN 1652
Nickel plated free cutting steel, no. 1.0737 / 1.0718, EN 10277
KP 1A, KP 5A, KP 6A, KP 7A
and KP 15A only
Stainless steel 18/8, no. 1.4306, EN 10088-2
Free cutting steel, no. 1.0737, EN 10277
Cold forming steel, no. 1.0338, EN 10139
Steel, no 1.0308, EN 10305
Free cutting steel, no. 1.0715, EN10277
Free cutting steel, no. 1.0718, EN 10277
Aluminium, no. AW-3005, EN 573
© Danfoss | DCS (rm) | 2019.03