MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.
Technical leaflet Coils for industrial valves B and A coils • Encapsulated coils with long operating life, even under extreme conditions • Standard coils for a.c. or d.c. • Standard coils from 12 V to 400 V, 50, 60 or 50/60 Hz • Standard coils available with 3 core cable, Danfoss terminal box or for DIN plugs • Coils can be fitted without use of tools • Coils can only be removed with use of tools Contents Coil type Enclosure B-series,13.5 mm system Power consumption a.c. d.c.
Technical leaflet Coils for industrial valves BA/BD Coils Weight 0.16 kg Without cable plug With protective cap With cable plug Technical data Design Voltage tolerance Power consumption, cut in Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating Ordering BA/BD Coils Compatibility for Valve type Coil type See data sheets for valves BA BA BD BA BD In accordance with VDE 0580 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c.
Technical leaflet Coils for industrial valves Coils type BB-Clip on version Weight 0.24 kg Technical data Ordering BB Coils L [mm] Without cable plug 62 With protective cap 77 With cable plug 85 Design In accordance with VDE 0580 Voltage tolerance 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10% Power consumption, cut in 44 VA a.c.
Technical leaflet Coils for industrial valves Coils type BE/BF-Clip on version Weight 0.30 kg With terminal box With 1 m cable Technical data L [mm] 94 65 Design In accordance with VDE 0580 Voltage tolerance 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10% Power consumption, cut in 44 VA a.c.
Technical leaflet Coils for industrial valves Coils type BG-Clip on version Weight 0.50 kg L [mm] With terminal box Technical data Design Voltage tolerance In accordance with VDE 0580 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10% 55 VA a.c. coils only Class H according to IEC 85 Terminal box; Pg 13.5 IP 67 Max.
Technical leaflet Coils for industrial valves Coils type BN-Clip on version Hum-free coil Weight 0.60 kg With 1 m cable Technical data Design Voltage tolerance In accordance with VDE 0580 220 and 380 V a.c. coils: +10%, -15%. 230/400 V a.c. coils: +6%, -10%. Other a.c. coils with NC valve: +10%, -15% Other a.c. coils with NO valve and all d.c. coils: ± 10% 24 VA Class H according to IEC 85 1 m 3-core flying lead ; Pg 13.5 IP 67 Max.
Technical leaflet Coils for industrial valves Coils type BO Eex m II T4 Technical data Ordering BO Coils • For explosion-risk environments, such as where flammable liquids and gases are produced, transported or tapped • Approvals for use in Zone 1 according to Directive 94/9/EC (ATEX 100A) EN50014 and EN50028 • Medium temperature: Up to +90°C • Ambient temperature: Up to +40°C • IP 67 version with 5 m 3-core flying lead • Seal kit as a.c.
Technical leaflet Coils for industrial valves Coils type BP EEx m II T4 Technical data Ordering BP Coils • The coils are suitable for use in installations where flammable liquids and gases are produced, transported or tapped • Approved for use in Zone 1 according to Directive 94/9/EC (ATEX 100A) EN60079 - 0 : 2006 EN60079 - 18 : 2004 EN50281 - 1 - 1 : 1998 • Grade of enclosure IP 67 • Supplied with 3 m moulded-in 3-core cable Voltage tolerance Insulation of coil windings Connection Enclosure, IEC 529
Technical leaflet Coils for industrial valves Coils type AB and AC AB Coil AC Coil Weight 0.05 kg Without cable plug With cable plug Technical data 1,411 mm In accordance with VDE 0580 Voltage tolerance ± 10% Power consumption, cut in AB 9.5 VA a.c. coils only AC 15.7 VA a.c. coils only Insulation of coil windings Class H according to IEC 85 Connection Spade connectors, 6.3 x 0.
Technical leaflet Coils type AK, AL and AM Technical data Coils for industrial valves AK Coil AL Coil Design Voltage tolerance Power consumption, cut in Insulation of coil windings Connection Enclosure, IEC 529 Ambient temperature Duty rating Ordering AK/AL/AM Coils Compatibility for Valve type Coil type AL AM AL AM In accordance with VDE 0580 ± 10% 10 VA 22.5 VA a.c.
Technical leaflet Coils for industrial valves Features Power Connector • Industrial standard 11 mm • For use with Danfoss coil type AB and AC • a.c./d.c. all voltages up to 250 V • Enclosure: Up to IP 65 • Ambient temperature: Up to +80°C Technical data Ordering Type Design Cable gland Poles Max. voltage Approvals GM 209 N (Bla.c.k) DIN 43650-B PG 9 2+l 250 V a.c./d.c. Protection class Max.
Technical leaflet Coils for industrial valves Features Technical data Power Connector • For use with Danfoss coils type AK, AL, AM, BA, BD and BB • AC/DC all voltages up to 250 V • Enclosure: Up to IP 65 • Ambient temperature: Up to +125°C Type Design Cable gland Poles Max. voltage Approvals Protection class Max. operating current Contact resistance Cable diameter Wire cross section Ambient temperature Materials Ordering Symbol GDM 2011 J (Grey) DIN 43650-A PG 11 2,3 + PE 250 V a.c./d.c.
Technical leaflet Coils for industrial valves Features Technical data Ordering Power (LED + Varistor) Indicator Connector • For use with Danfoss coils type AK, AL, AM, BA, BD and BB • 24 V a.c./d.c. and 230 V a.c. versions • Enclosure: Up to IP 65 • Ambient temperature: Up to +60°C Design Supply voltage tolerance Power consumtion Protection class Max.
Technical leaflet Coils for industrial valves Features Technical data Ordering Power (LED + Varistor) Indicator Connector • For use with Danfoss coil type AB and AC • 24 V a.c./d.c. and 230 V a.c. versions • Enclosure: Up to IP 65 • Ambient temperature: Up to +60°C Design Supply voltage tolerance Power consumtion Protection class Max. operating current Contact resistance Protection against wrong polarity Cable diameter Wire cross section Ambient temperature Materials Voltage LED colour 24 V a.c./d.
Technical leaflet Coils for industrial valves Universal electronic multi-timer Type ET 20 M • Outside adjustments • Light weight and small size • External adjustable timing from 1 minute to 45 minutes with 1 to 15 seconds drain open • One solid state timer fits all coil voltages from 24-240 V a.c • Light diodes for indication • All in one unit • Manual override (test button).