Submittal Sheet

Figure 2: EVR 2 - EVR 3 Solder and are connection
3
6
9
8
7
2
1
10
11
Figure 3: EVR 4 - EVR 6 - EVR 8 Solder and are connection
3
6
9
8
7
2
4
5
1
10
11
12
13
T
condensing temperature tc = 40 °C
pressure drop across valve ∆p = 0.8 bar
hot gas temperature th = 65 °C
subcooling of refrigerant ∆tsub = 4 K
For other refrigerants, please refer to Coolselector®2
Design and material
Table 3: Design and material for EVR 2, EVR 3, EVR 4, EVR 6, EVR 8
Pos. no.
1
2
3
4
5
6
7
8
9
10
11
12
13
T
Normally Open (NO) tube design
(1)
Manual stem is not available for EVR 4
(1)
Manual stem is not available for EVR 4
© Danfoss | Climate Solutions | 2021.02 AI249086497583en-001301 | 7
Solenoid valve, Type EVR 2 - EVR 40