Table Of Contents
Product specication
Technical data
Ambient temperature and enclosure for coil
See separate data sheet for solenoid and ATEX coils.
Max. working pressure
Figure 1: Max. working pressure in bar in relation to media temperature in °C.
-40
34.65
37.5
24.75
26
24.1
17.5
14.5
13.55
10.25
3
0-10-20-30
32 bar
45.2 bar
49 bar
°C
bar
Danfoss
32f986.02
WARNING:
Special note for EVR PED version: The EVR 2 - EVR 22 versions with solder connections and without manual stem can
be applied to 49 bar MWP.
NOTE:
Excluded from this EVR 22 with connections 1
3
⁄8 inch / 35 mm related to higher PED requirements.
Capacity
For K
v
values refer to the tables in Ordering.
The K
v
value of the water ow in [m
3
/h] at a pressure drop across valve of 1 bar, ρ = 1000 kg/m
3
.
See extended capacity tables on Coolselector®2.
Table 1: MOPD
Type
Opening
dierential pressure with standard coil ∆p [bar]
Min.
Max. (= MOPD) liquid
AC coil [10 W]
DC coil [20 W]
EVR 2 NC
0.00
38
33
EVR 3 NC
0.00
38
18
EVR 4 NC
0.03
38
28
EVR 6 NC
0.03
38
28
EVR 6 NO
0.03
21
21
EVR 8 NC
0.03
38
28
EVR 10 NC
0.03
38
20
EVR 10 NO
0.03
21
21
EVR 15 NC
0.03
38
20
EVR 15 NO
0.03
21
21
EVR 18 NC
0.03
38
20
EVR 20 NC
0.03
38
20
EVR 20 NO
0.03
19
19
EVR 22 NC
0.03
38
20
EVR 22 NO
0.03
19
19
EVR 25 NC
0.2
38
17
EVR 32 NC
0.2
38
17
EVR 40 NC
0.2
38
17
NOTE:
For higher MODP 12 W and 20 W AC coils are available on request
© Danfoss | Climate Solutions | 2021.02 AI249086497583en-001301 | 5