Submittal Sheet

Figure 24: EVR and Cable coil
L
Lc
L2
L1
L3
M
H2
H1
Danfoss
032F7328
Figure 25: EVR and DIN plug coil
Danfoss
032F73281
L
Lc
L2
L1
L3
M
H2
H1
Figure 26: EVR and Terminal box coil
Danfoss
032F73282
L
Lc
L2
L1
L3
M
H2
H1
Figure 27: Manual stem
H4
Danfoss
032F7330
Figure 28: End view
W1
W
Danfoss
032F73283
Dimensions and weights for EVR 15 - EVR 18 Solder connection
Table 10: Dimensions and weights for EVR 15 - EVR 18 Solder connection
Type
Connec‐
tion
Manual
opera‐
tion
H1
H2
H4
M min.
L
L1
L2
L3
Lc
W
W1
max.
Net
weight
without
coil
(1)
[in]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[kg]
Valve body
EVR 15
5
8
16
Yes
19
89
54
65
174
87
12
17
56
0.7
5
8
16
No
19
89
65
174
87
12
17
56
0.7
7
8
22
No
19
89
65
174
87
17
17
56
0.7
EVR 18
7
8
22
Yes
19
89
54
65
179
89.5
17
17
56
0.7
Coil
Cable coil
49
46
DIN plug coil
64
47
Terminal box coil 10 W
72
47
Terminal box coil 12 / 20 W
80
68
(1)
Net weight of coil for 10 W is approx. 0.3 kg and for 12 and 20 W is approx. 0.5 kg
(1)
Net weight of coil for 10 W is approx. 0.3 kg and for 12 and 20 W is approx. 0.5 kg
For 3D CAD models on individual code numbers visit store.danfoss.com
Solenoid valve, Type EVR 2 - EVR 40
© Danfoss | Climate Solutions | 2021.02 AI249086497583en-001301 | 14