Brochure
DKRCC.PB.BB0.C4.02 © Danfoss | DCS (ACR) | 2017.07
Danfoss A/S Nordborgvej 81, 6430 Nordborg, Denmark.
Telephone: +45 74 88 22 22. Fax: +45 7449 0949.
For more information with other
refrigerants, scan here and access our
Danfoss Coolselector® software.
coolselector.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed materials. Danfoss reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
For Manual operation EVR please
refer to Datasheet.
More than 20 refrigerants can
be used:
R22/R407C, R134a, R404A/R507,
R410A, R407A, R32, R290, R600,
R600a, R1234yf, R1234ze, R404A,
R407F, R125, R152A, R448A,
R449A, R452A, and R450A.
For a complete list of approved
refrigerants, visit www.products.
danfoss.com and search for
individual code numbers, where
refrigerants are
listed as part of
technical data
or check in
Coolselector
©
.
Fewer models. Broader scope.
Our revitalized EVR range saves on applied, development, and storage costs. Fewer
more versatile products are applicable to more applications and refrigerants while
being backward compatible.
Air Conditioning:
Superior performance in high
temperature applications (105 °C) and
optimized for variable refrigerant flow
conditions due to superior max. OPD
and min. OPD. Available connection
sizes from 6 mm to 42 mm - 1/4” to
2 1/8”. Reliable and versatile design.
Refrigeration:
Reliable and versatile valve platform
covers a wide range of functions,
applications, and refrigerants.
Improves life of refrigeration systems
contributing to food safety while
reducing energy consumption. Best in
class product features.
Food Retail:
One platform approved for lower-GWP
(Global Warming Potential) refrigerants,
including R290 propane. Tight solenoid
closure safeguards the system and with
enhanced flow characteristics for high
efficiency.
30%
Range streamlining
for optimized
logistics
EVR V2 type
Kv value [m³/h]
Opening dierential pressure with standard coil ∆p [bar]
Min.
Max. (= MOPD) liquid
AC coil [10 W] DC coil [20 W]
EVR 2 NC 0.15 0.00 38 33
EVR 3 NC 0.26 0.00 38 18
EVR 4 NC 0.7 0.03 38 28
EVR 6 NC 1.0 0.03 38 28
EVR 6 NO 1.0 0.03 21 21
EVR 8 NC 1.15 0.03 38 28
EVR 10 NC 1.47/2.2 0.03 38 20
EVR 10 NO 2.2 0.03 21 21
EVR 15 NC 3.3 0.03 38 20
EVR 15 NO 3.3 0.03 21 21
EVR 18 NC 3.9 0.03 38 20
EVR 20 NC 6.0 0.03 38 20
EVR 20 NO 6.0 0.03 19 19
EVR 22 NC 6.0 0.03 38 20
EVR 22 NO 6.0 0.03 19 19
EVR 25 NC 9.8 0.20 38 17
EVR 32 NC 16.7 0.20 38 17
EVR 40 NC 24.2 0.20 38 17