Submittal Sheet
Data sheet | Solenoid coil, Types BB, BE, BF, BG, and BN
© Danfoss | DCS (rja) | 2017.06
DKRCC.PD.BS0.F7.02 | 4
Ordering
BG solenoid coil with
terminal box IP67
Danfoss
18F61
Type
Valve type
Tambient
[°C]
Supply
voltage
[V]
Voltage
variation
Frequency
[Hz]
Power consumption
Code no.[W] [VA]
BG024AS
EVR 3 –
EVR 40
EVRC
EVRA
EVRAT
EVRS/
EVRST
EVM (NC/
NO)
-40T80 24 -15%, +10% 50 11 21 018F6807
BG048AS -40T80 48 -15%, +10% 50 12 26 018F6809
BG110AS -40T80 110 -15%, +10% 50 13 25 018F6811
BG230AS
-40T80 230 -15%, +10% 50 15 28
018F6801
-40T80 220 -15%, +10% 50 13 25
BG240AS -40T80 240 -15%, +10% 50 13 25 018F6802
BG400AS -40T80 380 / 400 -15%, +10% 50 12 26 018F6803
BG024BS -40T80 24 -15%, +10% 60 12 26 018F6815
BG110BS -40T80 110 -15%, +10% 60 16 29 018F6813
BG220BS -40T80 220 -15%, +10% 60 16 29 018F6814
BG012DS
EVR 2 – 8
EVR 25 – 40
EVRA 3 –
EVRA 15
(NC)
EVRA 25
– EVRA 40
(NC)
EVRAT 10
– EVRAT 15
(NC)
EVRS/
EVRST
3 – EVRS/
EVRST 15
EVM (NC/
NO)
-40T50 12 ±10% DC 20 – 018F6856
BG024DS -40T50 24 ±10% DC 16 – 018F6857
BG048DS -40T50 48 ±10% DC 20 – 018F6859
BG110DS -40T50 110 ±10% DC 16 – 018F6860
BG115DS -40T50 115 ±10% DC 19 – 018F6861
BG220DS -40T50 220 ±10% DC 20 – 018F6851
BG012DS
EVR 10 – 22
EVRC 15
– 20
EVRC 20
EVRA 20
EVRAT 20
EVRST 20
-40T50 12 ±10% DC 20 – 018F6886
BG024DS -40T50 24 ±10% DC 20 – 018F6887
BG048DS -40T50 48 ±10% DC 20 – 018F6889
BG110DS -40T50 110 ±10% DC 20 – 018F6890
BG220DS -40T50 220 ±10% DC 20 – 018F6881
See „Opening differential pressure“ under „Technical data“ for the valve concerned.
When replacing a coil with terminal box, it is sufficient to change the coil unit itself. Therefore, order coil with
DIN plugs and protective cap.