Install Instructions

DKRCC.PI.BS0.F3.2T | 1© Danfoss | DCS (az) | 2017.12
BB
Spade
10 W V AC /
18 W V DC /
special power
consumption
BB
Plug
10 W V AC /
18 W V DC /
special power
consumption
BE
Terminal box
10 W V AC /
18 W V DC /
special power
consumption
BE
DIN spade +
protection cap
10 W V AC /
18 W V DC /
special power
consumption
BF
Cable
10 W V AC /
18 W V DC /
special power
consumption
BG
Terminal box
20 W V DC /
special power
consumption
BG
Terminal box
12 W V AC /
special power
consumption
BN
Terminal box
Special
version incl.
20 W V AC
hum-free
Danfoss
18F9026.10
r > 55
mm
Danfoss
18F58
Danfoss
32U1774.10
Danfoss
18F9025
Torx TX10
80 90 Ncm
(0.59 0.66 lb-ft)
PG 13.5
320 370 Ncm
(2.36 2.73 lb-ft)
Danfoss
18F62
Danfoss
18F111
Danfoss
18F60
Danfoss
18F61
Danfoss
18F61
Danfoss
18F61
Danfoss
18F113.10
Danfoss
32F926.10
Cable strain relief
018R9666
Installation guide
Solenoid coil
Types BB, BE, BF, BG, and BN
018R9666
50 60 Ncm (0.39 0.44 lb-ft)
PG 11
250 375 Ncm
(1.84 2.77 lb-ft)
40 50 Ncm
(0.30 0.39 lb-ft)
Danfoss
18F114.10
Max. 8 mm (0.31 in)
Min. 4 mm (0.16 in)
(2.16 in)
Philips bits no. 1
40 50 Ncm (0.30 0.39 lb-ft)
ENGLISH
Type of control 1
Safety classification Class I
Ambient temperature 10 12 W V AC NC valve
10 12 W V AC NO valve
10 W dual frequency
20 W V AC
18 20 W V DC
-40 80 °C (-40 176 °F)
-40 55 °C (-40 131 °F)
-40 50 °C (-40 122 °F)
-40 50 °C (-40 122 °F)
-40 50 °C (-40 122 °F)
Humidity 0 100% R.H. (0 97% R.H. non-condensation condition
if IP level is below IPX5/NEMA X4)
Voltage variation
10 12 W single frequency
10 W dual frequency
20 W V AC
18 20 W V DC
-15% 10%
-10% 10%
-15% 10%
-10% 10%
Ball pressure test 200 °C
(392 °F)
Impulse withstand
voltage
Terminal box
Cable
Spade
Plug
Plug
4.0 kV at altitude <4000 m (13123 ft)
4.0 kV at altitude <4000 m (13123 ft)
4.0 kV at altitude <4000 m (13123 ft)
4.0 kV at altitude <2000 m (6561 ft)
3.1 kV 2000 m<altitude<4000 m
(6561<altitude<13123 ft)
Enclosure rate IPXX
Pollution degree PDX
Terminal box
Cable
Plug
Spade
Protection cap
IP67
IP67
IP65
IP00
IP20
PD4
PD4
PD3
PD3
PD3
Installation Integrated control
Incorporated control
Independently mounted control (IP65 and IP67)
Suitable cable and
conductor size for
plug and terminal box
ø6.6 ø11 mm (ø0.26 ø0.43 in)
0.75 1.5 mm² (21 15 AWG flexible cord)
Number of mating
for plug
10 times
Cable size
Cable conductor size
ø6.6 mm (ø0.26 in )
3 x 0.75 mm² (3 x 0.001 in
2
)
Installation and handling for cable: > 5 °C (41 °F)
- Only qualified personnel is allowed to install or maintain this product
- Disconnect the power when dismounting the coil
- Avoid direct exposure to alkaline conditions, use in neutral conditions is recommended
- Ensure that the O-ring is in place on the valve
- If the coil is used as independently mounted control, the end-user shall use a plastic cable
gland with strain relief
Special note for R152A, R32, R290, R600, R600a, R1234yf, and R1234ze:
The 13,5 mm coil (IP65/67) is validated in accordance to ISO 5149, IEC 60335 (ref. IEC/EN
60079-15). Ignition risk is evaluated in accordance to ISO 5149 and IEC 60335 (ref. IEC/EN
60079-15). Please make sure that there is no spark, arc on the spade connection during the
application.
Always Install a fuse ahead of the coil: rated current: two times of rated current, time lag:
medium, to avoid short circuit.
The coil used in an area of not more than pollution degree 2.
Follow the installation guide to mount the coil correctly, and apply o-ring for sealing to
prevent moisture penetrating inside the coil.
Safety note:
The 13.5 mm coil (IP65/67) can be applied on systems with R152A, R32, R290, R600, R600a,
R1234yf, and R1234ze as the working fluid.
For countries where safety standards are not an indispensable part of the safety system
Danfoss recommends the installer gets a third party approval of any system containing
flammable refrigerant.
Please follow specific selection criteria stated in the datasheet for these particular
refrigerants.
Note that 13.5 mm coil (IP65/67) has NOT been verified ATEX or IECEx or IEC 60079 series
zone 2 compliant. The product is only validated for systems in compliance with ISO5149, IEC
60335 (ref. IEC/EN 60079-15). It is the responsibility of the user to verify such compliance.
Improper use can cause explosion, fire, leakage potentially causing death, personal injury,
or damage to property.