Submittal Sheet
Technical leaflet Coils for solenoid valves
Danfoss A/S (AC-AKC / frz), 05 - 2008 DKRCC.PD.BS0.A3.02-520H1701 3
Features
Encapsulated coils with long operating life,
even under extreme conditions
Standard coils for a.c. or d.c.
Standard coils available with 3-core cable,
terminal box or DIN plugs
Standard coils from 12 V to 420 V, 50, 60
or 50/60 Hz
Standard coils dimensioned for max. opening
differential pressure (MOPD) of up to 21 bar
Coils can be fitted without the use of tools
Ambient temperature
10 or 12 W a.c. coil for NC (normally closed) valve:
−40 →+80°C
10 W a.c. coil
for NO (normally open) valve:
−40 →+55°C
20 W d.c. coil for NC and NO valve:
−40 →+50°C
Permissible voltage variation
10 and 12 W a.c. coils: +10 →−15% and as
double frequency coils: ±10%
a.c. coils for 220-230 / 380-400 V: +6 →−15%
and as double frequency coils: +6 →−10%
20 W d.c. coils: ±10%.
Enclosure
IP 67 with cable or terminal box
IP 20 with DIN plugs and protective cap
IP 65 with DIN socket
IP 00 with DIN plugs.
Approvals
See under the required solenoid valve.
Technical data
The coils are specially designed to operate in the
aggressive environment of high humidity and
temperature fluctuations that you find in most
refrigeration systems.
The new Clip-on fastening system ensures a
faultless installation and makes the coils easy
to mount and dismount. A Danfoss Clip-on coil
can be mounted without any tools at all, and
it is simple to dismount the coil by means of a
screwdriver.
The Clip-on coils are available for the
entire range of Danfoss solenoid valves for
refrigeration, freezing and air conditioning
purposes.
Introduction
3-core cable
The external thread in the screwed cable entry
suits flexible steel hose or corresponding cable
protection.
Terminal box
Leads are connected to terminal screws in the
terminal box. The box is fitted with a Pg 13.5
screwed entry for 6 → 14 mm cable.
Max. lead cross section: 2.5 mm
2
.
Connection
DIN plugs
The three pins on the coil can be fitted with spade
tabs, 6.3 mm wide (to DIN 46247).
The two current carrying pins can also be fitted
with spade tabs, 4.8 mm wide.
Max. lead cross section: 1.5 mm
2
.
Use of the protective cap supplied will prevent
inadvertent contact with live parts.
DIN socket
(to DIN 43650)
Leads are connected in the socket. The socket is
fitted with a Pg 11 screwed entry for
6 → 12 mm.