Data Sheet

Data Sheet Danfoss Ally™ Radiator Thermostat
4 | © Danfoss | FEC | 2020.09
AI319043912283en-000103
Mechanical Installation
1. Start by mounting the appropriate adapter.
Identify the needed adapter from the table
on pg 3.
2. Insert the batteries, then mount the thermostat
onto the adapter by turning it until you hear
a click.
3. Press and hold the button for 3 seconds.
The Danfoss Ally™ Radiator Thermostat is now
mounted and will display the current tempera-
ture.
Measuring the room
temperature
The Danfoss Ally™ Radiator Thermostat is measur-
ing the temperature with multiple built-in sensors
to ensure accurate control. Based on these read-
ings the room temperature is calculated for an area
approx. 20 cm in front of the display. This allows
the Danfoss Ally™ Radiator Thermostat to control
the actual room temperature very accurately.
Be aware that sources of cold or heat, e.g. fireplace,
direct sun or draft, might affect the function of the
Danfoss Ally™ Radiator Thermostat.
20 cm
Note! The displayed temperature is always the set