User manual

Adjusting the temperature
Set the desired temperature by press-
ing . Default setting is 21°C.
This also allows the temperature to be
changed temporarily during a setback
period, without having to change the
program or period.
If the comfort temperature is changed, e.g. from
21°C to 22°C, living eco® will remember this change,
and the comfort temperature will remain 22°C after
the next setback period.
Sets with lockshield valves
Lockshield valve (type RLV-D) is only included in sets with
code numbers 014G0011 and 014G0062.
Removal of
protective cap
Balancing
Do not cover the thermostat!
The thermostat opens and closes as determined by
the temperature around it. Therefore the sensor must
never be hidden behind thick curtains, furniture, etc.
Preparing the living sensor
for installation
The living sensor is supplied with two alkaline type AA
batteries, a 2 mm Allen key and adapters for Danfoss RA
valves.
Inserting the batteries
Remove the battery cover and insert
the batteries.
Make sure the batteries are oriented
correctly.
Setting time and date for the first time
(only living eco®)
Once the
batteries are
installed
The time will flash in the display - 23:59.
Set the time
Set hours using and press .
Set min. using and press .
Set date
Set date using and press .
Format: day/month/year (DD/MM/YYYY)
Confirm setting When flashes, press to confirm.
Installing the living sensor
M must be flashing on the display prior to installing.
If not, see installation mode in separate living eco®/
living connect® installation guide.
1. Mount the living sensor on the
valve and tighten with the Allen
key.
2. For living connect®:
Press for approx. 3 seconds to fix the sensor.
For living eco®:
Press for approx. 3 seconds to enter the function
menu.
When a small M flashes, press again to fix the sensor.
013R9548
013R9548
Danfoss Heating Solutions VIGWE102 © Danfoss 02/2012
INSTRUCTION
Combi-set with living sensor & bi-directional angle valve