Data Sheet
Dial / Operator / Sensor + Valve
FREE STANDING RADIATORS
The free-standing one-pipe low-pressure steam radiator is positioned where air
continually passes freely over the operator
FREE STANDING RADIATORS
The free-standing one-pipe low-pressure steam radiator is accessible, but air cannot
continually pass freely over the operator
CONVECTORS
The one-pipe low-pressure steam convector is inaccessible; room air cannot continually
pass freely over the valve
ENCLOSED RADIATORS
The cabinet enclosed radiator configuration requires that the dial and sensor be
mounted separately, away from the valve
Typical
Installation
Use air vent
PLUS
1/8” one-pipe
steam valve
Use air vent
PLUS
1/8” one-pipe
steam valve
Use dial / operator with remote
sensor. The sensor and capillary
tube may be extended up to 6’
and can be easily wall mounted.
Use operator with combined remote
dial / sensor. The dial/sensor and
capillary tube may be extended up
to 6’ and are wall mounted.
Use operator with separate remote
dial and remote sensor. Place the
remote sensor beneath the element
or on a draft-free wall. The remote
dial mounts on the enclosure or wall.
Use air vent
PLUS
Two 45 elbows
PLUS
1/8” one-pipe
steam valve
Data sheet
RA 2000 1PS
Thermostatic Radiator Valve
For Use on One-Pipe Low-Pressure
Steam Systems
Data sheet
VD.33.U1.02 © Danfoss 06/99
1
Use standard or tamper
resistant model with combined
dial/operator/
sensor. Always install the
operator horizontally
Use air vent
PLUS
1/8” one-pipe
steam valve
VDSXA122 ©Danfoss 07/07