Owner's Manual

TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE
The unit does not operate Not plugged in
The circuit breaker tripped or blown fuse
Turns on and off
frequently
The room temperature is hotter than normal
The door is open too often
The door is not closed completely
The temperature control is not set correctly
The door gasket does not seal properly
The unit does not have proper clearance
Vibrations Check that the keg cooler is level
The keg cooler seems to
make too much noise
The rattling noise may come from the fl ow of refrigerant, which is normal
Gurgling, caused by liquid refrigerant cycling is normal
Contraction and expansion of the inside walls may cause popping and
crackling noises
The keg cooler is not level
The door will not close
properly
The keg cooler is not level
The door was reversed and not properly reinstalled
The gasket is dirty
The shelves or stand are out of position
The keg is not properly centered in the unit
The casters are not attached
Excessive beer foam Ensure the beer line hose from the tower and the CO
2
air line hose from
the CO
2
regulator are attached to the correct connections on the coupler;
beer line to the top of the coupler, CO
2
air line to the side of the coupler
Check that there are no leaks in any connections
Ensure that the reed valve in the CO
2
connection at the coupler has a
hole in it
• The CO
2
pressure may be set too high; try turning the pressure down
Ensure that the check valve is inserted into the coupler
Ensure the beer lines are clean
Weak beer fl ow Ensure the beer line hose from the tower and the CO
2
air line hose from
the CO
2
regulator are attached to the correct connections on the coupler;
beer line to the top of the coupler, CO
2
air line to the side of the coupler
Check that there are no leaks in any connections
Ensure that the reed valve in the CO
2
connection at the coupler has a
hole in it
• The CO
2
pressure may be set too low; try turning the pressure up
Ensure there are no bends or kinks in any of the hoses that could impede
fl o w
Ensure the beer lines are clean
Danby Consumer Care: 1-800-263-2629
Hours of operation:
Monday to Thursday 8:30 am - 6:00 pm Eastern Standard Time
Friday 8:30 am - 4:00 pm Eastern Standard Time
Information in this manual is subject to change without notice.